Key result
Inpatient serum digoxin measurements are inappropriately performed before reaching steady state in 97% of cases.
Why the study?
Measurement of serum digoxin concentrations before steady-state is reached results in falsely low concentrations and may affect treatment safety, but the proportion and reasons for inappropriate sampling in hospitalized patients were unclear.
Observational (n=1,621)
No
A vast majority (97%) of serum digoxin measurements in hospitalized patients are performed inappropriately before steady-state is reached, highlighting a significant area for quality improvement and cost reduction.
High rate of premature digoxin assays may indicate ordering gaps; hypothesis-generating for stewardship programs to curb unnecessary testing.
INTRODUCTION: Measurement of serum digoxin concentrations before steady-state is reached results in a falsely low concentration, and may affect treatment safety. We evaluated the proportion of serum digoxin measurements performed before steady-state is reached and the reasons for inappropriate sampling in hospitalized patients. MATERIALS AND METHODS: Electronic medical records of patients hospitalized between January 2011 and December 2015 treated with oral digoxin, that had more than one digoxin measurement were included. Serum digoxin measurements performed before achievement of pharmacological steady state were considered as inappropriate. The chi-square and chi-square for trend tests were used to analyse the relationship between inappropriate measurements and age, gender, diagnosis, inpatient service, serum digoxin, potassium and creatinine concentrations. RESULTS: We evaluated 2065 hospital admissions for 1621 patients and 11,407 digoxin measurements. The time between consecutive measurements was 1.9 ± 2.4 days and 97% of all measurements were classified as inappropriate. There was no releationship between patient age, gender, serum creatinine concentration and inappropriate measurement. As opposed to expected, inappropriate digoxin measurement was higher when potassium concentrations were within the normal range (P = 0.025). Share of inappropriate determinations of digoxin was higher when concentrations > 2.6 nmol/L were recorded (P < 0.05). These measurements were requested most often in coronary care unit and cardiology department. CONCLUSIONS: In our study, inappropriate serum digoxin measurement was found to be very high although only one of the appropriateness criteria was evaluated. The findings reveal the need for some strategies to prevent inappropriate measurements and reduce costs.
No takes yet. Share an insight, caveat, or question.
Öncü et al. (2017) conducted an observational in Hospitalized patients treated with oral digoxin (n=1,621). Serum digoxin measurement was evaluated on Proportion of serum digoxin measurements performed before achievement of pharmacological steady state (<7 days). Among 11,407 serum digoxin measurements in hospitalized patients, 97% were performed inappropriately before steady-state was reached (less than 7 days after the previous measurement).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: