Key result
Ultrasound speckle tracking strongly correlates with tagged MRI for estimating LV torsion.
Why the study?
Left ventricular torsion is a key parameter of cardiac performance but is difficult to measure, though ultrasound speckle tracking imaging is potentially suitable due to angle-independence.
Observational (n=15)
Answers are grounded in this paper and cite their sources.
Imaging study demonstrates measurement of ventricular torsion using ultrasound speckle tracking in patients, highlighting noninvasive evaluation of myocardial mechanics.
OBJECTIVES: We sought to examine the accuracy/consistency of a novel ultrasound speckle tracking imaging (STI) method for left ventricular torsion (LVtor) measurement in comparison with tagged magnetic resonance imaging (MRI) (a time-domain method similar to STI) and Doppler tissue imaging (DTI) (a velocity-based approach). BACKGROUND: Left ventricular torsion from helically oriented myofibers is a key parameter of cardiac performance but is difficult to measure. Ultrasound STI is potentially suitable for measurement of angular motion because of its angle-independence. METHODS: We acquired basal and apical short-axis left ventricular (LV) images in 15 patients to estimate LVtor by STI and compare it with tagged MRI and DTI. Left ventricular torsion was defined as the net difference of LV rotation at the basal and apical planes. For the STI analysis, we used high-frame (104 +/- 12 frames/s) second harmonic two-dimensional images. RESULTS: Data on 13 of 15 patients were usable for STI analysis, and LVtor profile estimated by STI strongly correlated with those by tagged MRI (y = 0.95x + 0.19, r = 0.93, p < 0.0001, analyzed by repeated-measures regression models). The STI torsional velocity profile also correlated well with that by the DTI method (y = 0.79x + 2.4, r = 0.76, p < 0.0001, by repeated-measures regression models) with acceptable bias. CONCLUSIONS: The STI estimation of LVtor is concordant with those analyzed by tagged MRI (data derived from tissue displacement) and also showed good agreement with those by DTI (data derived from tissue velocity). Ultrasound STI is a promising new method to assess LV torsional deformation and may make the assessment more available in clinical and research cardiology.
No takes yet. Share an insight, caveat, or question.
Notomi et al. (2005) reported an observational. Ultrasound speckle tracking imaging (STI) vs. Tagged magnetic resonance imaging (MRI) and Doppler tissue imaging (DTI) was evaluated on Correlation of left ventricular torsion profile (r = 0.93, p=<0.0001). Ultrasound speckle tracking imaging estimation of left ventricular torsion strongly correlated with tagged MRI and Doppler tissue imaging.
Synapse has enriched 10 related papers. Consider them for comparative context: