Key result
Da Silva's cone repair is linked to a ~48% reduction in functional RV end-diastolic volume.
Why the study?
Da Silva's cone repair is a novel surgical technique for Ebstein's anomaly, and its effects on tricuspid competency, right ventricular size, and function needed evaluation.
Does Da Silva's cone repair improve tricuspid competency and right ventricular size and function in patients with Ebstein's anomaly?
Observational (n=20)
Does Da Silva's cone repair improve tricuspid competency and right ventricular size and function in patients with Ebstein's anomaly?
Da Silva's cone repair for Ebstein's anomaly effectively restores tricuspid valve competence and reduces right ventricular size, though it is associated with an initial decrease in right ventricular ejection fraction.
Answers are grounded in this paper and cite their sources.
May support cone repair for RV remodeling in Ebstein's; leaves open prospective validation of functional outcomes.
OBJECTIVES: Da Silva's cone repair is a novel technique for surgical reconstruction of the tricuspid valve and the right ventricle (RV) in Ebstein's anomaly. The technique consists of extensive leaflet mobilization, longitudinal plication of the atrialized ventricle and cone-shaped reconstruction of the tricuspid valve, allowing for leaflet-to-leaflet coaptation. We evaluated the influence of Da Silva's cone repair on tricuspid competency, right ventricular size and function. METHODS: From February 2010 until July 2013, 20 patients (median age 30.0 years, range 6.6-68.3 years) underwent Da Silva's cone repair. A 4- to 6-mm interatrial communication was left in all patients. Echocardiographic studies and magnetic resonance imaging (MRI) before and after the repair were evaluated. RESULTS: Median follow-up was 11 (0.5-36) months. There were 2 early deaths and no late death. Echocardiography at follow-up revealed mild or absent tricuspid regurgitation in 16 patients. Two patients showed moderate tricuspid insufficiency. MRI studies showed that the mean functional RV end-diastolic volume decreased after surgery (pre 334 [135-656] ml; post 175 [115-404] ml, P < 0.001). The mean RV ejection fraction decreased (pre 47 ± 10%; post 35 ± 13%, P = 0.001), and the mean antegrade net stroke volume of the RV increased (pre 65 ± 28 ml; post 75 ± 30 ml, P = 0.057). CONCLUSIONS: Da Silva's cone repair for Ebstein's anomaly creates excellent valve function in all patients. Consecutively, the size of the RV decreases and the antegrade net stroke volume increases 6 months after the operation.
No takes yet. Share an insight, caveat, or question.
Lange et al. (2014) conducted an observational in Ebstein's anomaly (n=20). Da Silva's cone repair vs. Pre-operative baseline was evaluated on functional RV end-diastolic volume (p=<0.001). Da Silva's cone repair for Ebstein's anomaly decreased mean functional right ventricular end-diastolic volume from 334 ml to 175 ml.