Key result
Magnesium-based sirolimus-eluting scaffold shows 6.8% target lesion failure at three years with no scaffold thrombosis.
Why the study?
The safety and performance of a magnesium-based sirolimus-eluting metal scaffold beyond the scaffold resorption period were not well established.
Does a magnesium-based sirolimus-eluting metal scaffold provide long-term safety and performance in patients with de novo coronary lesions?
Does a magnesium-based sirolimus-eluting metal scaffold provide long-term safety and performance in patients with de novo coronary lesions?
The DREAMS 2G magnesium-based sirolimus-eluting bioresorbable scaffold demonstrated sustained safety with low complication rates and no scaffold thrombosis up to 3 years.
Answers are grounded in this paper and cite their sources.
Supports further scaffold evaluation in coronary lesions; leaves open randomized confirmation before practice change.
AIMS: We aimed to evaluate the safety and performance of a magnesium-based sirolimus-eluting metal scaffold at three-year follow-up to assess vessel response two years beyond scaffold resorption. METHODS AND RESULTS: BIOSOLVE-II is an international, multicentre first-in-man study, including 123 patients with de novo lesions. Predilatation was mandatory and post-dilatation was left to the discretion of the investigators. Dual antiplatelet therapy was recommended for six months. At three years, 91.1% of patients were angina-free and 8.0% were on dual antiplatelet therapy. The target lesion failure rate was 6.8% (n=8: two cardiac deaths, one target vessel myocardial infarction and five target lesion revascularisations). No probable or definite scaffold thrombosis was observed. Imaging follow-up was voluntary and serial angiographic assessment at 6, 12, and 36 months was available in 25 patients. In these, a slight increase in in-segment and in-scaffold late lumen loss and diameter stenosis was observed between 12 and 36 months (by 0.11±0.28 mm and 0.13±0.30 mm for late lumen loss, and by 3.8±10.1% and 4.1±10.2% for diameter stenosis). CONCLUSIONS: Two years beyond the resorption period of a sirolimus-eluting bioresorbable metal scaffold built from a proprietary magnesium alloy, complication rates remained low. In the patients with serial angiographic assessment, late lumen loss and diameter stenosis did not increase substantially beyond the resorption period.
No takes yet. Share an insight, caveat, or question.
Haude et al. (2020) studied de novo coronary lesions (n=123). magnesium-based sirolimus-eluting metal scaffold (DREAMS 2G) was evaluated on target lesion failure. The magnesium-based sirolimus-eluting metal scaffold (DREAMS 2G) demonstrated a low target lesion failure rate of 6.8% at 3 years, with no probable or definite scaffold thrombosis.