TAVR following TMVR achieves 100% procedural success using careful wire positioning and self-expandable valves.
Why the study?
Severe aortic stenosis following transcatheter mitral valve replacement (TMVR) is increasingly observed, but experience with subsequent transcatheter aortic valve replacement (TAVR) is limited.
Is TAVR technically feasible and safe in patients who have previously undergone TMVR?
Case Report (n=3)
Is TAVR technically feasible and safe in patients who have previously undergone TMVR?
TAVR following previous TMVR is technically feasible and can be safely performed with careful attention to wire position and proper valve selection.
Supports feasibility of TAVR post-TMVR with specific techniques; leaves open safety, durability, and generalizability questions.
Background Transcatheter mitral valve replacement (TMVR) in deteriorated prostheses, rings or mitral annular calcification are being performed more frequently. Inadvertently, we are starting to see patients who develop severe aortic stenosis following TMVR. Simultaneous transcatheter aortic valve replacement (TAVR)/TMVR has been previously reported, but almost all are performed in the order of TAVR first then followed by TMVR. Methods We included three patients who underwent TAVR following TMVR. The patients subsequently presented with symptomatic aortic stenosis or insufficiency. All procedures were performed from September 2015 to July 2017. Results All cases underwent successful TAVR after TMVR. There were several technical points. First, a balloon expandable valve was used for the initial case, but because of the interaction between the balloon and TMVR valve, we elected to use self-expandable valves for the subsequent cases. Secondly, it is critical to confirm that the wire is not traversing a cell of TMVR valve frame. This can be confirmed by fluoroscopy steered to steep left anterior oblique (LAO)/Cranial view to show that the wire is outside of any cells. Thirdly, when the space between the left ventricular outflow tract (LVOT) and the TMVR frame is narrow, there can be an interaction between the self-expanding valve nose-cone and TMVR valve which can bias the transcatheter valve towards the aorta. Conclusion TAVR following TMVR poses several technical challenges. We highlight some of the obstacles encountered during the procedure, and offer potential solutions based on our experience. TAVR following previous TMVR can be safely performed with careful attention to wire position and proper valve selection.
No takes yet. Share an insight, caveat, or question.
Kaneko et al. (2018) conducted a case report in Symptomatic aortic stenosis or insufficiency following TMVR (n=3). Transcatheter aortic valve replacement (TAVR) was evaluated on Successful TAVR after TMVR. TAVR following previous TMVR was successfully performed in 100% of cases (3 of 3), demonstrating feasibility with careful attention to wire position and self-expandable valve selection.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: