Key result
A free margin length difference <5 mm during valve-sparing aortic root replacement improved 3-year freedom from residual regurgitation or valve replacement compared to ≥5 mm.
Why the study?
Morphologic risk factors influencing outcomes after valve-sparing aortic root replacement for aortic valves with paracommissural fenestrations are not well defined.
Cohort (n=145)
Yes
Answers are grounded in this paper and cite their sources.
In patients undergoing valve-sparing aortic root replacement for valves with paracommissural fenestrations, inhomogeneities of cusp-free margin lengths ≥5 mm and additional prolapse are associated with significantly worse outcomes.
OBJECTIVES: To define morphologic risk constellations during valve-sparing aortic root replacement (VSARR) for aortic valves with paracommissural fenestrations. METHODS: Patients from the multicentre prospective intention-to-treat VSARR-registry German Aortic Root Repair Registry (GEARR) were screened for paracommissural cusp fenestrations. We studied a combined end-point of residual aortic regurgitation (rAR) on post-cardiopulmonary bypass (CPB) transesophageal echocardiography (TEE), mid-term progress of rAR (transthoracic echocardiography) and aortic valve replacement for AR. RESULTS: Of a total of 762 registry patients (operated 2016-2024), 145 were identified with ≥1 paracommissural cusp fenestration. Eighteen patients (12%) were not treated as planned but underwent composite valved graft (CVG) implantation. Mean follow-up time was 3 years. Upon post-CPB TEE, rAR grade 1 or 2 were present in 44 (33%) and 3 (2%) patients. 50% of patients with fenestrations in more than one cusp showed early progression of rAR. At 3 years, freedom from the combined end-point was 78% (99% CI 74-79%) for the complete study cohort. Patients with a maximum free margin length difference of <5 mm, reflecting balanced root anatomy with respect to sinus and cusp sizes, had a significantly better outcome than those with ≥5 mm: at 3 years, freedom from the combined end-point was 86% (99% CI 80-91%) vs 41% (99% CI 38-46%, P = 0.011). Outcome was worst for patients with cusp prolapse and a free margin length difference of >5 mm (30% vs 70%, P = 0.018). CONCLUSIONS: Fenestrations in more than one cusp, inhomogeneities of cusp-free margin lengths, and additional prolapse are associated with inferior outcome after VSARR for valves with paracommissural fenestrations. CLINICAL TRIAL REGISTRATION NUMBER: DRKS00007872.
No takes yet. Share an insight, caveat, or question.
Kari et al. (2025) conducted a cohort in Aortic valves with paracommissural fenestrations (n=145). Maximum free margin length difference of <5 mm vs. Maximum free margin length difference of ≥5 mm was evaluated on Combined end-point of residual aortic regurgitation on post-CPB TEE, mid-term progress of residual aortic regurgitation, and aortic valve replacement for aortic regurgitation (p=0.011). A free margin length difference <5 mm during valve-sparing aortic root replacement improved 3-year freedom from residual regurgitation or valve replacement compared to ≥5 mm.
Synapse has enriched 10 related papers. Consider them for comparative context: