Key result
Computerized analysis of FHR tracings shows poor agreement with physician interpretations.
Why the study?
The level of agreement in the interpretation of antepartum fetal heart rate tracings among physicians and between physicians and computer analysis was uncertain.
Does interpretation of antepartum fetal heart rate tracings by obstetricians agree with a computer analysis program in high-risk pregnant women?
Observational (n=54)
Does interpretation of antepartum fetal heart rate tracings by obstetricians agree with a computer analysis program in high-risk pregnant women?
There is poor agreement among obstetricians and between obstetricians and computer analysis in the interpretation of antepartum fetal heart rate tracings, and a scoring system does not improve inter-observer agreement.
Answers are grounded in this paper and cite their sources.
May limit confidence in fetal heart rate interpretations for high-risk pregnancies; leaves open need for standardized validation.
OBJECTIVE: To compare the interpretation of fetal heart rate (FHR) tracings by three obstetricians with that of a computer analysis program. METHODS: Our study population consisted of high-risk pregnant women referred as outpatients for antepartum FHR monitoring. A total of 121 FHR tracings, from a series of 54 consecutive women, were interpreted by three physicians and a computer program (Oxford Sonicaid System 8000, Oxford Sonicaid Ltd., Chichester, UK). The physicians used a modified FHR scoring system to interpret the tracings. Total scores were categorized as 0-4: abnormal, 5-7: questionable, and 8-10: normal. The computer program used overall variation, categorized as normal: longer than 30 ms, abnormal: shorter than 20 ms, and questionable: 20-30 ms. RESULTS: Significant differences were found among the physicians and between the physicians and the computer analysis for the individual elements of FHR tracings. There was very good agreement between two physicians and the computer in the assessment of the FHR baseline. When physicians used a FHR scoring system to classify the tracings as normal, questionable, or abnormal, the agreement was poor (kappa values ranged from -0.037 to 0.28). The computerized analysis identified two FHR tracings as questionable but both were classified as normal by all three physicians. CONCLUSIONS: The level of agreement in the interpretation of FHR tracings was poor among physicians and between physicians and the computer analysis. A FHR scoring system did not improve the level of agreement between physicians.
No takes yet. Share an insight, caveat, or question.
Bracero et al. (2000) conducted an observational in High-risk pregnancy (n=54). Computer analysis program (Oxford Sonicaid System 8000) vs. Physician interpretation (three obstetricians) was evaluated on Agreement in the interpretation of fetal heart rate tracings (kappa -0.037 to 0.28). Computerized analysis of fetal heart rate tracings showed poor agreement with physician interpretations, with kappa values ranging from -0.037 to 0.28.