Key result
The Convergent hybrid procedure with confluent extended posterior left atrial wall ablation achieved 64.5% single-procedure freedom from atrial fibrillation through 24 months in advanced cases.
Why the study?
Ablation techniques targeting the posterior left atrial wall to eliminate existing and future AF substrates in persistent or longstanding persistent AF patients require evaluation for intermediate-term outcomes.
Does the Convergent hybrid procedure with confluent extended posterior left atrial wall ablation prevent atrial arrhythmia recurrence in patients with persistent or longstanding persistent atrial fibrillation?
Observational (n=57)
No
Does the Convergent hybrid procedure with confluent extended posterior left atrial wall ablation prevent atrial arrhythmia recurrence in patients with persistent or longstanding persistent atrial fibrillation?
The Convergent hybrid procedure utilizing confluent extended posterior left atrial wall epicardial ablation combined with endocardial mapping and ablation achieved a 64.5% single-procedure freedom from atrial fibrillation at 24 months in patients with advanced non-paroxysmal atrial fibrillation.
Intermediate outcomes after confluent posterior LA ablation in hybrid AF procedures reported; leaves open its comparative efficacy and durability.
Here, we report intermediate follow-up details after using a technique of confluent posterior left atrial wall epicardial ablation designed to eliminate both existing and future atrial fibrillation (AF) substrates. The method is part of the Convergent hybrid procedure for AF ablation. In this study, multiple confluent epicardial ablations with radiofrequency energy were delivered, spanning the vertical and transverse dimensions of the posterior left atrium, along with facilitated pulmonary vein isolation (PVI). Endocardial mapping and ablation were performed to complete PVI and to ablate the cavotricuspid isthmus. All patients were followed clinically and using two-to-four weeks of continuous monitoring at six, 12, and 24 months, respectively. The average length of follow-up was 488 days. Of the 57 largely unselected patients with persistent or longstanding persistent AF (NPAF), mean duration of AF was 5.6 years. Single procedure freedom from AF through 24 months was 64.5%, and that for all arrhythmias, was 58.9%. Sixty-eight percent of patients were off antiarrhythmic drugs. Four patients (7%) required a second endocardial ablation procedure. A sub-analysis of the observed arrhythmia burden present through follow-up showed this to be small (ie, <1%) in the majority of patients involved in this study. In conclusion, the extended posterior left atrial wall ablation technique discussed here, as part of the Convergent hybrid method, achieved notable single-procedure success in a particularly challenging series of patients with NPAF.
No takes yet. Share an insight, caveat, or question.
Robinson et al. (2017) conducted an observational in Non-paroxysmal atrial fibrillation (n=57). Convergent hybrid procedure with confluent extended posterior left atrial wall ablation was evaluated on Single procedure freedom from atrial fibrillation through 24 months. The Convergent hybrid procedure with confluent extended posterior left atrial wall ablation achieved 64.5% single-procedure freedom from atrial fibrillation through 24 months in advanced cases.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: