Key result
Signal-averaged bipolar chest ECGs successfully extract surface His-bundle activity in 30% of cases.
Why the study?
The feasibility of detecting His-bundle activity non-invasively from the body surface using signal averaging was uncertain.
Can His-bundle activity be detected from the body surface using signal averaging of bipolar chest lead electrocardiograms?
Observational (n=10)
Can His-bundle activity be detected from the body surface using signal averaging of bipolar chest lead electrocardiograms?
Signal averaging of bipolar chest lead electrocardiograms can non-invasively detect His-bundle activity in a minority of patients, demonstrating feasibility.
Noninvasive His recording succeeds rarely; leaves open feasibility for clinical use pending technical advances and validation.
Electrocardiograms were recorded from human patients using a bipolar chest lead together with simultaneous His-bundle electrograms. These were then subjected to the technique of signal averaging in an attempt to extract His-bundle activity from the surface record. This was successful in three out of 10 cases subjected to the truly non-invasive surface technique. Methods are discussed by which the technique could be improved.
No takes yet. Share an insight, caveat, or question.
Furness et al. (1975) reported an observational. Signal averaging of bipolar chest lead electrocardiograms was evaluated on Extraction of His-bundle activity from the surface record. Signal averaging of bipolar chest lead electrocardiograms successfully extracted His-bundle activity from the surface record in 30% (3 of 10) of cases.