Key result
Flexible band or ring tricuspid annuloplasty shows ~90% 5-year survival for functional TR.
Why the study?
Late outcomes after tricuspid annuloplasty using a flexible band or ring for functional tricuspid regurgitation during mitral valve surgery were assessed to understand durability and predictors of recurrent TR.
Does tricuspid annuloplasty using a flexible band or ring provide acceptable late outcomes for functional tricuspid regurgitation during mitral valve surgery?
Cohort (n=220)
No
Does tricuspid annuloplasty using a flexible band or ring provide acceptable late outcomes for functional tricuspid regurgitation during mitral valve surgery?
Tricuspid annuloplasty using a flexible band or ring during mitral valve surgery provides acceptable late survival and freedom from recurrent tricuspid regurgitation, with better outcomes when performed before TR deterioration.
May support flexible annuloplasty during mitral surgery for functional TR; leaves open need for RCTs on timing and durability.
BACKGROUND: We assessed late outcome after tricuspid annuloplasty (TAP) using a flexible band or ring for functional tricuspid regurgitation (FTR). METHODS AND RESULTS: We reviewed 220 consecutive patients (mean age, 65.4±11.4 years) who underwent TAP for FTR during mitral valve surgery between January 2000 and December 2010. Indications for TAP included the following: (1) TR grade greater than mild; (2) history of right heart failure; (3) atrial fibrillation; and (4) systolic pulmonary artery pressure (SPAP) ≥50 mmHg. The mean follow-up period was 4.4±2.6 years. Overall hospital mortality was 5.5% (12/220). The 5- and 10-year survival rates were 90.2±2.1% and 82.4±5.6%, respectively. Freedom from recurrent TR at 8 years was 78.0±6.6%. Twenty patients had a greater than mild TR grade at final follow-up. Elevated SPAP was a predictor of recurrent TR (hazard ratio, 1.091; P=0.0003), which was associated with advanced age, atrial fibrillation, rheumatic etiology and preoperative TR grade. There was a significant difference in freedom from valve-related events between residual TR greater than mild and less than moderate (log-rank test, P=0.0464). Factors affecting residual TR were preoperative TR grade (OR, 7.368; P=0.0267) and mitral valve replacement (OR, 4.369; P=0.0402). CONCLUSIONS: Late outcome of TAP in the present series was acceptable. Late outcome can be improved by performing TAP before deterioration of TR.
No takes yet. Share an insight, caveat, or question.
Fukunaga et al. (2015) conducted a cohort in Functional tricuspid regurgitation (n=220). Tricuspid annuloplasty using a flexible band or ring was evaluated on 5-year survival rate. Tricuspid annuloplasty using a flexible band or ring for functional tricuspid regurgitation demonstrated acceptable late outcomes, with a 5-year survival rate of 90.2% and 8-year freedom from recurrent regurgitation of 78.0%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: