Answers are grounded in this paper and cite their sources.
In the event of a fire, smoke can reduce visibility and hinder evacuation, putting tunnel users at risk. The smoke must be controlled to prevent its entry into the evacuation passages, ensuring that the safe areas are maintained. In several Japanese road tunnels, the passages are pressurized by fans, generating airflow from the passage towards the main tunnel. This study theoretically predicted the critical velocity required to prevent buoyancy-driven smoke infiltration. Richardson numbers and nondimensional density defects along the tunnel ceiling were calculated using a simplified ceiling jet model. Vertical temperature rise distributions, expressed as exponential functions, were evaluated based on the ceiling temperature at the same distance from the fire source. The critical velocity was then predicted from the smoke height obtained by the vertical temperature distribution using the integral ratio method. The results were validated against experimental data from a model tunnel.
No takes yet. Share an insight, caveat, or question.
Kume et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: