Key result
A single high-intensity defibrillator shock induces LV failure in dogs, reducing cardiac output by ~43%.
Why the study?
A selective, non-ischemic, non-pharmacological left ventricular failure model is needed to evaluate cardiac augmentation techniques in a closed chest animal.
Does a high-intensity defibrillator shock induce selective left ventricular failure in a closed-chest dog model?
Does a high-intensity defibrillator shock induce selective left ventricular failure in a closed-chest dog model?
A high-intensity transventricular defibrillator shock successfully induces a non-ischemic, non-pharmacological left ventricular failure model in closed-chest dogs, useful for evaluating cardiac augmentation techniques.
Answers are grounded in this paper and cite their sources.
High-intensity shocks may model selective LV failure in dogs; leaves open validation for testing cardiac augmentation techniques.
Selective left ventricular failure was induced in 13 acute anesthetized, closed chest dogs ranging in weight from 18-26 kg. Failure was induced by passing a single, high intensity pulse of current from a defibrillator connected to a left ventricular catheter electrode and a left chest electrode. The intensity of the myocardial damaging shock was related to the predicted current required for transventricular defibrillation, based on heart weight. Thermodilution cardiac output, left ventricular pressure, impedance stroke volume, the cardiac electrogram, and lead II ECG were recorded, along with the pressure impedance (volume) loop, which is a measure of stroke work. It was found that the cardiac output decreased with increasing current intensity. Immediately following the high current shock, cardiac output, and stroke work decreased. In some animals, with a moderate intensity shock, there was a transient increase in cardiac output, followed by a decrease. In the five animals that were monitored continuously for 4 hours, the average percent reduction in cardiac output at this time was 42.5% for an average current overdose ratio of 5.39. The energy setting on the defibrillator to obtain this range of reduction in cardiac output was 175-350 joules. The method described herein is easily applied to the closed chest animal and will allow evaluation of the pumping capabilities of cardiac augmentation techniques, such as dynamic cardio-myoplasty and the skeletal muscle ventricle.
No takes yet. Share an insight, caveat, or question.
Geddes et al. (1994) studied Left ventricular failure (n=13). High intensity pulse of current from a defibrillator was evaluated on Reduction in cardiac output. A single high-intensity defibrillator shock (175-350 joules) induced selective left ventricular failure in dogs, resulting in an average 42.5% reduction in cardiac output at 4 hours.