Key result
Fontan operation linked to progressively worsening global longitudinal and circumferential strain rates over 10 years.
Why the study?
There are little data on how echocardiographic parameters of ventricular function change over time in patients with single ventricle heart disease after Fontan operation.
Observational (n=40)
No
Global longitudinal and circumferential strain rates worsen progressively over 10 years following the Fontan operation, potentially serving as early markers of cardiac dysfunction.
Answers are grounded in this paper and cite their sources.
Serial post-Fontan echo indices need prospective validation; leaves open their utility for risk stratification or intervention timing.
BACKGROUND: While numerous indices have been developed in an attempt to quantify ventricular function in patients with single ventricle heart disease after Fontan, there are little data on how these parameters change over time. METHODS: A retrospective observational study was performed of individuals who underwent Fontan operation at Children's Hospital of Philadelphia (CHOP) in 2006 and 2007. Measurements of fractional area change (FAC), tricuspid annular planar systolic excursion (TAPSE), myocardial performance index (MPI), systolic to diastolic (s/d) ratio, and myocardial strain and strain rate were made offline. A composite outcome of protein-losing enteropathy (PLE), plastic bronchitis, transplant, or death was created, and change in function was compared between those who did and those who did not meet the outcome. RESULTS: There were 312 echocardiograms from 40 unique patients (75% male, 55% dominant right ventricle). The aggregate mean values for most assessed parameters were worse than what would be expected for a healthy age-matched population. The global longitudinal strain rate increased (worsened) by 0.014 (1/s) per year (P = .02), and the global circumferential strain rate increased (worsened) by 0.011 (1/s) per year (P = .01). There was no difference in the rate of change of ventricular function in the 6 patients who met the composite endpoint vs those who did not. CONCLUSION: This study demonstrates that global longitudinal strain rate and global circumferential strain rate decrease over 10 years following Fontan operation. These measures of ventricular performance may be early signs of cardiac dysfunction that predate more obvious echocardiographic signs of deterioration.
No takes yet. Share an insight, caveat, or question.
Campbell et al. (2020) conducted an observational in Single ventricle heart disease after Fontan operation (n=40). Time after Fontan operation vs. Patients without the composite outcome was evaluated on Longitudinal change in global longitudinal strain rate (0.014 (1/s) per year, p=.02). Over 10 years following Fontan operation, global longitudinal strain rate worsened by 0.014 (1/s) per year and global circumferential strain rate worsened by 0.011 (1/s) per year.
Synapse has enriched 10 related papers. Consider them for comparative context: