Key result
Noninvasive ICON and echocardiography correlate with clinical low cardiac output detection in post-cardiac surgery children.
Why the study?
The optimal method for hemodynamic monitoring after corrective cardiac surgery in critically ill pediatric patients remains uncertain.
Does non-invasive cardiometry (ICON) correlate with echocardiography and clinical status for hemodynamic monitoring in pediatric patients post-cardiac surgery?
Cross-Sectional (n=40)
Does non-invasive cardiometry (ICON) correlate with echocardiography and clinical status for hemodynamic monitoring in pediatric patients post-cardiac surgery?
Echocardiography and electrical cardiometry parameters correlate significantly with each other and with clinical signs of low cardiac output in pediatric patients following congenital heart surgery.
Answers are grounded in this paper and cite their sources.
May support non-invasive cardiometry correlation with clinical status post-pediatric cardiac surgery; leaves open whether it improves outcomes or guides therapy.
Background: Accurate hemodynamic monitoring is essential when identifying and treating critically ill pediatric patients. Effective perioperative care directed by sophisticated hemodynamic monitoring can lower problems and enhance results, even though the best monitoring method is still up for debate. Objective: to compare monitoring methods of cardiac output and systemic hemodynamics post-cardiac surgery and its correlation to the clinical status of patients (reflected by clinical signs and laboratory assessment) and outcome, focusing on non-invasive cardiometry and echocardiography. Methodology: A cross-sectional study was conducted on 40 pediatric patients under five years old who underwent corrective cardiac surgery for congenital heart lesions. Hemodynamic parameters were assessed using echocardiography and ICON, alongside clinical evaluation and biomarkers (BNP and lactate), at 6 and 24 hours postoperatively. Statistical analysis was employed to identify significant correlations and trends. Results: Significant hemodynamic changes were observed in the immediate post-operative period. Clinical assessment detected low cardiac output in 47% of patients at 6 hours, decreasing to 45% at 24 hours. TAPSE and ejection fraction, measured via echocardiography, showed significant correlations with clinical signs of low cardiac output at 6 and 24 hours, respectively. ICON parameters, such as thoracic fluid content (TFC), demonstrated significant trends, correlating with fluid balance and time on bypass. However, ICON lacked the precision of echocardiography for certain measures; its continuous, non-invasive monitoring provided valuable insights into hemodynamic trends. Conclusion: Hemodynamic monitoring post-operative cardiac surgery with early management of instability decreases the risk of complications and prolonged hospital stay. Clinical assessment of low cardiac output symptoms is crucial in the hemodynamic monitoring of patients, paying attention to vital data. Echocardiography and electrical cardiometry parameters have significant correlations with each other, including contractility (TAPSE, CI) and fluid assessment values (IVC collapsibility and TFC). BNP levels are best used not as a "stand-alone" test but in conjunction with existing multivariable risk indexes.
No takes yet. Share an insight, caveat, or question.
Ibrahim et al. (2025) conducted a cross-sectional in congenital heart lesions (n=40). Echocardiography and non-invasive cardiometry (ICON) was evaluated on Correlation of monitoring methods to clinical status and outcome. In pediatric patients post-cardiac surgery, clinical assessment detected low cardiac output in 47% at 6 hours, with echocardiography and ICON parameters showing significant correlations.
Synapse has enriched 10 related papers. Consider them for comparative context: