Key result
Adjusting time delay and sampling frequency improves entropy-based distinction of pathological ECG signals.
Why the study?
The dependence of approximate entropy (ApEn) and sampling entropy (SampEn) on time delay (τ) and sampling frequency (Fs) for ECG and EEG signals was not well characterized, affecting reliable clinical classification.
Adjusting the time delay parameter (τ) to values larger than 1 in entropy estimators improves the robust classification of normal versus pathological ECG and EEG signals while reducing computational cost.
Answers are grounded in this paper and cite their sources.
Entropy measures may refine ECG/EEG classification; leaves open routine adoption pending validation studies.
Electrocardiography (ECG) and electroencephalography (EEG) signals provide clinical information relevant to determine a patient’s health status. The nonlinear analysis of ECG and EEG signals allows for discovering characteristics that could not be found with traditional methods based on amplitude and frequency. Approximate entropy (ApEn) and sampling entropy (SampEn) are nonlinear data analysis algorithms that measure the data’s regularity, and these are used to classify different electrophysiological signals as normal or pathological. Entropy calculation requires setting the parameters r (tolerance threshold), m (immersion dimension), and τ (time delay), with the last one being related to how the time series is downsampled. In this study, we showed the dependence of ApEn and SampEn on different values of τ, for ECG and EEG signals with different sampling frequencies (Fs), extracted from a digital repository. We considered four values of Fs (128, 256, 384, and 512 Hz for the ECG signals, and 160, 320, 480, and 640 Hz for the EEG signals) and five values of τ (from 1 to 5). We performed parametric and nonparametric statistical tests to confirm that the groups of normal and pathological ECG and EEG signals were significantly different (p < 0.05) for each F and τ value. The separation between the entropy values of regular and irregular signals was variable, demonstrating the dependence of ApEn and SampEn with Fs and τ. For ECG signals, the separation between the conditions was more robust when using SampEn, the lowest value of Fs, and τ larger than 1. For EEG signals, the separation between the conditions was more robust when using SampEn with large values of Fs and τ larger than 1. Therefore, adjusting τ may be convenient for signals that were acquired with different Fs to ensure a reliable clinical classification. Furthermore, it is useful to set τ to values larger than 1 to reduce the computational cost.
No takes yet. Share an insight, caveat, or question.
Espinosa et al. (2020) studied Normal and pathological ECG and EEG signals. Different values of time delay (τ) and sampling frequencies (Fs) was evaluated on Separation between entropy values of regular and irregular signals (p=<0.05). Adjusting time delay (τ) and sampling frequency significantly affected the separation of normal and pathological ECG and EEG signals using ApEn and SampEn (p < 0.05).
Synapse has enriched 10 related papers. Consider them for comparative context: