Key result
Low 125 Hz ECG sampling introduces ~4% error in Sample Entropy HRV versus 2000 Hz.
Why the study?
Linear HRV parameters are sensitive to ECG sampling frequency and low sampling frequency may cause clinical misinterpretation; the effect on SampEn-based HRV needed investigation.
Observational (n=10)
Absolute Event Rate: 3.5% vs 0%
SampEn based HRV indices computed from RR interval time series with low ECG sampling frequencies should be interpreted with caution due to induced errors.
Low-frequency ECG sampling may bias SampEn-HRV estimates; leaves open need for validated sampling standards in HRV research.
Biomedical signals carry important information about the behaviour of the living systems under study. A proper processing of these signals in principle enhances their physiological and clinical information. Analysis of variations in the instantaneous heart rate time series using the beat to-beat RR intervals (the RR tachogram) is known as heart rate variability (HRV) analysis. Sample entropy (SampEn), refined version of approximate entropy (ApEn), is a nonlinear complexity measure used to quantify the irregularity of a RR interval time series without biasing. An increase in SampEn is an indicator of increases in complexity. Linear HRV parameters are very sensitive to ECG sampling frequency and low sampling frequency may result in clinically misinterpretation of HRV. In this study consequences of errors in SampEn based HRV induced by ECG sampling frequency have been investigated. The error induced in SampEn based HRV was found to be a function of ECG sampling frequency and RR interval data length. The relative error in SampEn was approximately 3.5%.for medium and long term data (N=500, 1000 respectively) and less than 2% for short term data (N=200) at low ECG sampling frequency of 125 Hz with respect to reference values at 2000 Hz. Therefore the SampEn based HRV indices computed from RR interval time series with low ECG sampling should be regarded with caution. The finding of this study can be partly used as a reference for the optimal ECG sampling frequency for the SampEn-based HRV assessment.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2014) conducted an observational in Healthy (n=10). Low ECG sampling frequency (125 Hz) vs. 2000 Hz ECG sampling frequency was evaluated on Relative error in Sample Entropy (SampEn) based HRV. A low ECG sampling frequency of 125 Hz induced a relative error of approximately 3.5% in Sample Entropy based HRV for medium and long-term data compared to a 2000 Hz reference.