This is the authors' abstract. We don't add key points for this paper.
A combined experimental and modeling study was performed to evaluate the relation between sorbent characteristics and process performance for solid sorption postcombustion CO 2 capture. A pulverized coal (PC) and a natural gas combined cycle (NGCC) power plant were considered, addressing CO 2 and H 2 O sorption. The measured isotherms for PEI/silica sorbent were implemented in an equilibrium-based flow sheeting model. The PC regeneration heat demand is 3.9 GJ/ton CO 2 captured. This is lower than that of the NGCC and, though a direct comparison is not valid, similar to a literature MEA case. Solid sorption systems hold the promise to be energetically superior to MEA: a 2-fold increase in CO 2 adsorption capacity (to 4.4 mmol/g) yields a regeneration heat demand of 3.3 GJ/ton, even when accompanied by a similar increase in H 2 O adsorption capacity.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Dijkstra et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: