Key result
Transcatheter PFO closure achieves ~90% effective closure, with highest residual shunting in Gore Helex.
Why the study?
The rate of residual shunting after transcatheter PFO closure varies by device, and effective closure rates among devices used off-label in the US were not well characterized.
Does the choice of device affect the effective closure rate in patients undergoing transcatheter PFO closure?
Observational (n=167)
No
Does the choice of device affect the effective closure rate in patients undergoing transcatheter PFO closure?
Transcatheter PFO closure has a high overall success rate of 90%, but residual shunting varies significantly by device, being highest with the 30-mm Gore Helex device.
Device selection may influence residual shunting after PFO closure; observational data leaves open need for randomized device comparisons.
OBJECTIVES: To assess the effective closure rate among devices used for transcatheter patent foramen ovale (PFO) closure, and to discuss the management of patients with large residual shunts. BACKGROUND: Several devices are used off-label for transcatheter closure of a PFO in the United States. The rate of residual shunting after PFO closure varies by device. Failure of effective closure poses risk of a recurrent cerebrovascular event, persistent migraine, or recurrent orthodeoxia. METHODS: Patients who underwent PFO closure in the Cardiac Catheterization Laboratory at UCLA between 2001 and 2013 and had baseline and adequate follow-up transcranial Doppler studies following device placement were enrolled in the study. RESULTS: Of 167 patients whose records were analyzed, effective PFO closure occurred in 90% (150/167) of patients. The highest effective closure rate was with the Amplatzer Septal Occluder (ASO; 100%), followed by the Amplatzer Cribriform (93%), Gore Helex (90%), Amplatzer PFO (86%), and CardioSEAL (86%) device. The highest rate of residual shunting was observed after placement of the 30-mm Gore Helex device (55%). Of the 17 patients with a residual shunt, three required a repeat PFO closure procedure due to a significant residual shunt associated with recurrent pulmonary emboli or profound orthodeoxia. All three patients received an ASO which successfully closed the residual shunt. CONCLUSIONS: Transcatheter PFO closure has a high success rate, but a moderate residual shunt occurs in about 10% of cases. The observed incidence of residual shunting after PFO closure is significantly larger with the 30-mm Helex device.
No takes yet. Share an insight, caveat, or question.
Matsumura et al. (2014) conducted an observational in Patent foramen ovale (n=167). Transcatheter PFO closure devices was evaluated on Effective PFO closure. Transcatheter PFO closure achieved an overall effective closure rate of 90%, with the highest residual shunting rate (55%) observed with the 30-mm Gore Helex device.