Key result
Pacemaker infective endocarditis incidence rises ~3-fold over recent decades.
Why the study?
The epidemiology and clinical features of infective endocarditis involving pacemaker devices over time were not well characterized.
Observational (n=25)
No
The incidence of infective endocarditis on pacemaker devices has significantly increased over the past decades and is associated with severe complications and high early mortality.
Rising pacemaker IE incidence signals need for closer post-implant surveillance; leaves open optimal prevention amid expanding device use.
AIMS: Use of cardiac pacing devices has grown in recent years. Our aim was to evaluate changes in epidemiology and clinical features of infective endocarditis (IE) involving pacemaker devices in a large series of IE over the last 27 years (1987-2013). METHODS AND RESULTS: From 1987 to December 2013, 413 consecutive IE cases were diagnosed in our hospital. During this period, 7424 pacemaker devices were implanted (6917 pacemakers, 239 implantable cardiac defibrillators, 158 resynchronization devices, and 110 resynchronization/defibrillator devices). All consecutive cases of IE on pacemaker devices were included and analysed. Infective endocarditis on pacemaker devices represented 6.1% of all endocarditis cases (25 patients), affecting 3.6/1000 of all implanted pacemakers. Its proportion increased from 1.25% of all endocarditis in 1987-1993 to 4.08% in 1994-2000, 7.69% in 2001-2007 and 9.32% in 2008-2013 (P < 0.01). Its incidence also increased from 1.4/1000 of all pacemaker implants in the period of 1987-1993 to 2.5/1000 in 1994-2000, 3.3/1000 in 2001-2007 and 4.5/1000 implanted devices in 2008-2013 (P < 0.05). Mean age of patients was 68 years, and 80% were male. Causative microorganisms predominantly were Staphylococci (84%: Staphylococcus aureus 48%, Staphylococcus epidermidis 36%). Rate of severe complications was high: persistent sepsis in 60% of cases, heart failure in 20%, and stroke in 12%. Device was removed in 19 patients (76%), mostly by surgery (18 of the 19 cases). Early mortality was 24% (33% of medically, 21% of surgically treated patients, P = 0.82). CONCLUSION: Infective endocarditis on pacemaker devices has shown an increasing incidence during the past decades, representing almost 10% of all IE in the last 6 years. This is a severe disease, with a high rate of severe complications and requiring removal of device in most cases. In spite of therapy, early mortality is high.
No takes yet. Share an insight, caveat, or question.
Carrasco et al. (2015) conducted an observational in Infective endocarditis on pacemaker devices (n=25). Pacemaker devices was evaluated on Incidence of infective endocarditis on pacemaker devices (p=<0.05). The incidence of infective endocarditis on pacemaker devices increased significantly from 1.4/1000 implants in 1987-1993 to 4.5/1000 in 2008-2013 (P<0.05), with an early mortality of 24%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: