Key result
Tetrilimus biodegradable-polymer EES shows similar 12-month MACE rates compared to durable-polymer Xience.
Why the study?
Clinical differences between biodegradable polymer-coated and durable polymer-coated everolimus-eluting stents in all-comer patients undergoing PCI were unclear.
Does a biodegradable polymer-coated everolimus-eluting stent reduce major adverse cardiac events compared to a durable polymer-coated everolimus-eluting stent in all-comer patients undergoing PCI?
Observational (n=417)
Yes
Does a biodegradable polymer-coated everolimus-eluting stent reduce major adverse cardiac events compared to a durable polymer-coated everolimus-eluting stent in all-comer patients undergoing PCI?
Absolute Event Rate: 4.2% vs 4.9%
p-value: p=0.740
Biodegradable polymer-coated everolimus-eluting stents demonstrated similar 12-month safety and efficacy outcomes compared to durable polymer-coated stents in all-comer PCI patients.
Similar MACE rates support comparable real-world safety in all-comer PCI; leaves open whether biodegradable polymers confer long-term advantages in randomized trials.
AIM: The purpose of the present study was to examine whether clinical differences exist between the biodegradable polymer (BDP)-coated Tetrilimus everolimus-eluting stent (EES) and the durable polymer (DP)-coated Xience EES by comparing the major adverse cardiac event (MACE) rate at 12 months in all-comer patients. METHODS: This study was designed as a multicentre, observational, retrospective, investigator-initiated study between January 2016 and October 2016. Two hundred thirteen patients who underwent percutaneous coronary intervention (PCI) with the BDP-EES were compared with 204 patients who underwent PCI with the DP-EES, irrespective of lesion complexity, comorbidities and acute presentation. The primary end point was MACE defined as a composite of cardiac death, myocardial infarction and target lesion revascularization. RESULTS: Baseline clinical and lesion characteristics of both the groups were similar, although the BDP-EES group had a significantly higher number of patients with diabetes mellitus (39.9% vs. 30.4%; p = 0.042) and type C lesion (67.4% vs. 48.1%; p < 0.001) than the DP-EES group. The 12-month MACE rate was 4.2% for the BDP-EES group versus 4.9% for the DP-EES group (p = 0.740). Mortality was lower in the BDP-EES group than in the DP-EES group (0.9% vs. 2.0%; p = 0.441). CONCLUSION: The present comparative analysis shows that the BDP-coated Tetrilimus EES was as safe and effective as the DP-coated Xience EES during the 12-month follow-up period despite complex lesion characteristics.
No takes yet. Share an insight, caveat, or question.
Abhyankar et al. (2019) conducted an observational in Percutaneous coronary intervention (n=417). Biodegradable polymer (BDP)-coated Tetrilimus everolimus-eluting stent (EES) vs. Durable polymer (DP)-coated Xience EES was evaluated on MACE defined as a composite of cardiac death, myocardial infarction and target lesion revascularization (p=0.740). Biodegradable polymer-coated Tetrilimus everolimus-eluting stents resulted in a similar 12-month MACE rate compared to durable polymer-coated Xience stents (4.2% vs 4.9%; p=0.740).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: