Why the study?
The vessel healing process after implantation of biodegradable polymer vs durable polymer everolimus-eluting stents in STEMI lesions remains unclear.
Does biodegradable polymer everolimus-eluting stent improve neointimal coverage compared to durable polymer everolimus-eluting stent in STEMI patients?
Does biodegradable polymer everolimus-eluting stent improve neointimal coverage compared to durable polymer everolimus-eluting stent in STEMI patients?
In STEMI patients, biodegradable polymer everolimus-eluting stents showed comparable early neointimal coverage but superior competent strut coverage at 1 year compared to durable polymer stents.
Answers are grounded in this paper and cite their sources.
BP-EES may support better mid-term strut coverage in STEMI; leaves open clinical outcome impact.
BACKGROUND: The vessel healing process after implantation of biodegradable polymer (BP) and durable polymer (DP) everolimus-eluting stent (EES) in ST-elevation myocardial infarction (STEMI) lesions remains unclear. METHODS AND RESULTS: We conducted a multicenter prospective randomized controlled trial to compare early (2 weeks) and mid-term (12 months) vascular responses after implantation of BP-EES vs. DP-EES in STEMI patients. In this prespecified subanalysis, serial coronary angioscopy (CAS) analysis was performed in 15 stents in the BP-EES arm (n=10 patients) and 14 stents in the DP-EES arm (n=10 patients). At the 2-week follow-up, there was no significant difference in the estimated marginal means of the neointimal coverage grade (primary endpoint) between the 2 arms (mean [±SE] 0.00±0.00 in both arms; P>0.999). There were no significant differences between the BP-EES and DP-EES groups in the yellow color grade (1.046±0.106 vs. 0.844±0.114, respectively; P=0.201) or the presence of thrombus (77.8% vs. 88.8%, respectively; P=0.205). At 12 months, competent strut coverage, defined as yellow color grade ≤1, no thrombus, and a neointimal coverage grade ≥1 was achieved more frequently in the BP-EES than DP-EES arm (85.2% vs. 53.1%; adjusted odds ratio 2.11 [95% confidence interval 1.26-3.53]; P=0.023). CONCLUSIONS: Neointimal coverage 2 weeks after implantation of BP-EES and DP-EES in STEMI lesions was comparable on CAS evaluation. However, at 1 year, BP-EES was independently associated with competent strut coverage.
No takes yet. Share an insight, caveat, or question.
Nakatani et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: