Why the study?
The vessel healing process after implantation of biodegradable polymer vs durable polymer everolimus-eluting stents in STEMI lesions remains unclear.
Does biodegradable polymer everolimus-eluting stent improve neointimal coverage compared to durable polymer everolimus-eluting stent in STEMI patients?
Does biodegradable polymer everolimus-eluting stent improve neointimal coverage compared to durable polymer everolimus-eluting stent in STEMI patients?
In STEMI patients, biodegradable polymer everolimus-eluting stents showed comparable early neointimal coverage but superior competent strut coverage at 1 year compared to durable polymer stents.
BP-EES may support better mid-term strut coverage in STEMI; leaves open clinical outcome impact.
BACKGROUND: The vessel healing process after implantation of biodegradable polymer (BP) and durable polymer (DP) everolimus-eluting stent (EES) in ST-elevation myocardial infarction (STEMI) lesions remains unclear. METHODS AND RESULTS: We conducted a multicenter prospective randomized controlled trial to compare early (2 weeks) and mid-term (12 months) vascular responses after implantation of BP-EES vs. DP-EES in STEMI patients. In this prespecified subanalysis, serial coronary angioscopy (CAS) analysis was performed in 15 stents in the BP-EES arm (n=10 patients) and 14 stents in the DP-EES arm (n=10 patients). At the 2-week follow-up, there was no significant difference in the estimated marginal means of the neointimal coverage grade (primary endpoint) between the 2 arms (mean [±SE] 0.00±0.00 in both arms; P>0.999). There were no significant differences between the BP-EES and DP-EES groups in the yellow color grade (1.046±0.106 vs. 0.844±0.114, respectively; P=0.201) or the presence of thrombus (77.8% vs. 88.8%, respectively; P=0.205). At 12 months, competent strut coverage, defined as yellow color grade ≤1, no thrombus, and a neointimal coverage grade ≥1 was achieved more frequently in the BP-EES than DP-EES arm (85.2% vs. 53.1%; adjusted odds ratio 2.11 [95% confidence interval 1.26-3.53]; P=0.023). CONCLUSIONS: Neointimal coverage 2 weeks after implantation of BP-EES and DP-EES in STEMI lesions was comparable on CAS evaluation. However, at 1 year, BP-EES was independently associated with competent strut coverage.
No takes yet. Share an insight, caveat, or question.
Nakatani et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: