Key result
Preoperative CT membranous septum length varies notably across the cardiac cycle, reaching a minimum at 90% R-R.
Why the study?
The changes in membranous septum length during the cardiac cycle and by different measurement methods using preoperative CT for TAVR were not well characterized.
Does the measurement method and cardiac cycle phase affect the evaluated membranous septum length in patients undergoing preoperative CT for TAVR?
Cross-Sectional (n=34)
No
Does the measurement method and cardiac cycle phase affect the evaluated membranous septum length in patients undergoing preoperative CT for TAVR?
Membranous septum length varies significantly depending on the measurement method and cardiac cycle phase, highlighting the importance of standardizing measurements during diastole for TAVR planning.
Answers are grounded in this paper and cite their sources.
Variability in CT membranous septum length by phase and method warrants caution in TAVR planning; leaves open standardized diastolic protocols for prospective validation.
PURPOSE: The purpose of this study was to evaluate the changes in membranous septum (MS) length during the cardiac cycle and by measurement methods using the preoperative computed tomography (CT) images for transcatheter aortic valve replacement (TAVR). METHOD: Among 34 consecutive patients who underwent preoperative contrast-enhanced CT for TAVR, we measured MS lengths by three measurement methods (coronal, stretched, and reformatted coronal view method) at 10% intervals in the cardiac cycle. RESULT: MS lengths differed between the three measurement methods in all cardiac phases. Moderate correlations were observed between the MS lengths measured by the coronal view method and the other two methods. In contrast, strong correlations were observed between the MS lengths measured by the stretched view method and the reformatted coronal view method. The frequencies of the minimum and maximum MS lengths during the cardiac cycle tended to be highest at R-R 90% and R-R 30%, respectively. The median MS lengths at R-R 90% were smaller than those at R-R 30% in all measurement methods. CONCLUSION: The MS length in patients undergoing contrast-enhanced CT for TAVR varies notably depending on the cardiac cycle and measurement methods. When evaluating MS length, it is crucial to consider the measurement method and to perform measurements during diastole in order to evaluate the minimum value during the cardiac cycle.
No takes yet. Share an insight, caveat, or question.
Hirai et al. (2023) conducted a cross-sectional in Patients undergoing preoperative contrast-enhanced CT for TAVR (n=34). Measurement of membranous septum length by three methods (coronal, stretched, and reformatted coronal view) during the cardiac cycle was evaluated on Changes in membranous septum (MS) length during the cardiac cycle and by measurement methods. Membranous septum length measured on preoperative CT for TAVR varied notably depending on the cardiac cycle and measurement method, with minimum lengths typically observed at R-R 90%.