Key result
Brief rectal distension in IBS alters autonomic HRV markers, though responses habituate across repetitive sessions.
Why the study?
The most suitable heart rate variability parameters for assessing autonomic nervous system activity in response to brief rectal distension in IBS patients were not established.
Which heart rate variability parameters are most sensitive for assessing autonomic responses to brief rectal distension in patients with Irritable Bowel Syndrome?
Observational (n=17)
Which heart rate variability parameters are most sensitive for assessing autonomic responses to brief rectal distension in patients with Irritable Bowel Syndrome?
The Sympathetic Index and SDNN/SDNN Index are the most sensitive HRV parameters for assessing autonomic responses to rectal distention in IBS patients, with responses diminishing over repetitive sessions due to habituation.
May support HRV monitoring of ANS responses in IBS; hypothesis-generating and requires validation before clinical use.
Heart rate variability (HRV) has been used to measure autonomic nervous system (ANS) activity noninvasively. The purpose of this study was to identify the most suitable HRV parameters for ANS activity in response to brief rectal distension (RD) in patients with Irritable Bowel Syndrome (IBS). IBS patients participated in a five-session study. During each visit, an ECG was recorded for 15 min for baseline values and during rectal distension. For rectal distension, a balloon was inflated in the rectum and the pressure was increased in steps of 5 mmHg for 30 s; each distension was followed by a 30 s rest period when the balloon was fully deflated (0 mmHg) until either the maximum tolerance of each patient was reached or up to 60 mmHg. The time-domain, frequency-domain and nonlinear HRV parameters were calculated to assess the ANS activity. The values of each HRV parameter were compared between baseline and RD for each of the five visits as well as for all five visits combined. The sensitivity and robustness/reproducibility of each HRV parameter were also assessed. The parameters included the Sympathetic Index (SI); Root Mean Square of Successive Differences (RMSSD); High-Frequency Power (HF); Low-Frequency Power (LF); Normalized HF Power (HFn); Normalized LF Power (LFn); LF/HF; Respiratory Sinus Arrhythmia (RSA); the Poincare Plot's SD1, SD2 and their ratio; and the pNN50, SDSD, SDNN and SDNN Index. Data from 17 patients were analyzed and compared between baseline and FD and among five sessions. The SI was found to be the most sensitive and robust HRV parameter in detecting the ANS response to RD. Out of nine parasympathetic parameters, only the SDNN and SDNN Index were sensitive enough to detect the parasympathetic modulation to RD during the first visit. The frequency-domain parameters did not show any change in response to RD. It was also observed that the repetitive RD in IBS patients resulted in a decreased autonomic response due to habituation because the amount of change in the HRV parameters was the highest during the first visit but diminished during subsequent visits. In conclusion, the SI and SDNN/SDNN Index are most sensitive at assessing the autonomic response to rectal distention. The autonomic response to rectal distention diminishes in repetitive sessions, demonstrating the necessity of randomization for repetitive tests.
No takes yet. Share an insight, caveat, or question.
Ali et al. (2023) conducted an observational in Irritable Bowel Syndrome (n=17). Brief rectal distension vs. Baseline was evaluated on Change in heart rate variability (HRV) parameters. Brief rectal distension in IBS patients elicited autonomic responses best detected by the Sympathetic Index and SDNN/SDNN Index, though responses diminished in repetitive sessions due to habituation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: