Key result
Early post-transplant LV systolic dysfunction is linked to greater 1-year coronary lumen diameter loss.
Why the study?
The role and predictive value of early left ventricular systolic function and other factors on development of cardiac allograft vasculopathy after heart transplantation were unclear.
Cohort (n=121)
p-value: p=0.006
Impaired left ventricular systolic function within the first week after heart transplantation is an independent predictor of early cardiac allograft vasculopathy development.
Cardiac allograft vasculopathy (CAV) is a major cause of death more than 1 year after heart transplantation. We evaluated the role and possible predictive value of different etiological factors on development of CAV as diagnosed by quantitative coronary angiography (QCA). A total of 121 patients were studied with baseline QCA and 117 had a follow-up study at 1 year to assess the relationship of mean lumen diameter loss (MLDL) in main coronary arteries to immunological and non-immunological factors potentially affecting long-term survival. Out of them, 103 patients were males (85%), 114 (94%) patients were Caucasians and mean age was 48.5 +/- 10 years. Univariate analysis showed that MLDL at 1 year was inversely related to echocardiographic fractional shortening (FS) measured within the first week after transplantation (p = 0.0098) and to intracranial hemorrhage as cause of donor death (p = 0.04) and was directly related to male donors (p = 0.0008), domino transplants (p = 0.037) and donor negative cytomegalovirus (CMV) status (p = 0.022). Multivariate analysis showed that initial FS (p = 0.006) and donor intracranial hemorrhage as a cause of death (p = 0.042) were inversely related to MLDL whereas donor male sex (p = 0.003) and prednisolone treatment throughout the first year (p = 0.012) were directly related. Thus, left ventricular systolic dysfunction early after heart transplantation was associated with subsequent development of CAV.
No takes yet. Share an insight, caveat, or question.
Bolad et al. (2005) conducted a cohort in Cardiac allograft vasculopathy (n=121). Early left ventricular systolic dysfunction was evaluated on Mean lumen diameter loss (MLDL) in main coronary arteries at 1 year (p=0.006). Early left ventricular systolic dysfunction after heart transplantation was independently associated with greater mean lumen diameter loss at 1 year (p=0.006).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: