Key result
SAPIEN 3 postdilatation is linked to a ~15% larger 1-year effective orifice area.
Why the study?
Postdilatation after transcatheter heart valve implantation was associated with larger aortic valve areas in registries, but its specific effects remain poorly understood.
Does postdilatation improve THV diameter and effective orifice area in patients undergoing transcatheter aortic valve replacement using SAPIEN 3?
Observational (n=224)
Does postdilatation improve THV diameter and effective orifice area in patients undergoing transcatheter aortic valve replacement using SAPIEN 3?
Postdilatation after SAPIEN 3 TAVR implantation significantly increases THV diameter and effective orifice area up to 1 year, with less acute recoil.
Answers are grounded in this paper and cite their sources.
Postdilatation was associated with larger THV diameter and sustained EOA to 1 year; leaves open long-term clinical impact.
Background Postdilatation after transcatheter heart valve (THV) implantation was associated with larger aortic valve areas in large‐scale registries; however, the specific effects of postdilatation are poorly understood. Methods and Results Among a total of 224 consecutive patients who underwent transcatheter aortic valve replacement using SAPIEN 3, 121 patients (54.0%) underwent postdilatation (same contrast volume: N = 101, +1 ml: N = 17, +2 ml: N = 3). THV diameter was assessed (a) during, (b) after implantation, (c) during postdilatation, and (d) after postdilatation by quantitative fluoroscopy. In the overall patients (N = 224), acute recoil was observed from during implantation (23.0 ± 2.0 mm) to after implantation (22.5 ± 2.0 mm, p < .001) with an absolute recoil of 0.52 ± 0.25 mm. After postdilatation (N = 121), THV diameter significantly increased from 22.5 ± 2.0 mm to 22.9 ± 2.1 mm (p < .001), with smaller absolute recoil (0.39 ± 0.21 mm, p < .001). Compared with those who did not undergo postdilatation, patients who underwent postdilatation had larger postprocedural THV area assessed by multi‐slice computed tomography (471.4 ± 78.1 mm2 vs. 447.5 ± 76.3 mm2, p = .02) and larger effective orifice area (EOA) assessed by echocardiography throughout 1 year (at 30 day, 1.66 ± 0.33 cm2 vs. 1.45 ± 0.27 cm2, p < .001; at 6 month, 1.66 ± 0.33 cm2 vs. 1.44 ± 0.29 cm2, p < .001; at 1 year, 1.69 ± 0.38 cm2 vs. 1.47 ± 0.30 cm2, p < .001). Conclusions Postdilatation after implantation of the SAPIEN 3 valve produced a larger THV diameter with less acute recoil, followed by larger EOA throughout 1 year. Further studies are needed to evaluate the impact of postdilatation on long‐term clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Kawaguchi et al. (2019) conducted an observational in Transcatheter aortic valve replacement (n=224). Postdilatation vs. No postdilatation was evaluated on Effective orifice area (EOA) at 1 year (p=<.001). Postdilatation after SAPIEN 3 valve implantation resulted in a larger effective orifice area at 1 year compared to no postdilatation.
Synapse has enriched 10 related papers. Consider them for comparative context: