Key result
Percutaneous PFO closure is linked to transient ~22% lower LA anterior wall strain rate.
Why the study?
The influence of atrial septal occluders on left atrial function after percutaneous closure of patent foramen ovale has not been thoroughly studied.
Does percutaneous closure of patent foramen ovale with a septal occluder alter left atrial function in patients undergoing the procedure?
Observational (n=25)
Does percutaneous closure of patent foramen ovale with a septal occluder alter left atrial function in patients undergoing the procedure?
Percutaneous PFO closure with a septal occluder causes transient alterations in segmental left atrial function at 3 months that fully resolve by 6 months.
Answers are grounded in this paper and cite their sources.
Transient LA strain changes after PFO closure resolve by 6 months; leaves open device-specific effects on outcomes in prospective cohorts.
BACKGROUND: The influence of atrial septal occluders in left atrial (LA) function after percutaneous closure of patent foramen ovale (PFO) has not been thoroughly studied. METHODS: Twenty-five patients (mean age 40.7 ± 12 years) undergoing percutaneous PFO closure were enrolled in this study. Transthoracic echocardiogram (TTE) was performed 3 and 6 months before the procedure. Volumetric indices (active emptying fraction: LA AEF, expansion index: LA EI, and passive emptying fraction: LA PEF), strain and strain rate (SR), were calculated during the contractile, reservoir, and conduit LA phases for the lateral, anterior, and inferior LA walls with TTE. RESULTS: After 3 months, a decrease in the SR of the LA anterior wall was observed (from 2.12 ± 0.22 to 1.66 ± 0.26, P < 0.045), while the LA lateral wall strain was found to be increased (from 0.708 ± 0.15 to 0.783 ± 0.159, P < 0.001). Moreover, simultaneously LA AEF was greater compared with baseline (from 31.0 ± 1.6 to 34.0 ± 1.6, P < 0.004). However, all these alterations reversed at 6 months. CONCLUSIONS: Segmental LA function is altered transiently after percutaneous PFO closure with a septal occlude. The LA anterior wall SR decreases, while the lateral wall strain increases. The impact of these alterations needs further clarification.
No takes yet. Share an insight, caveat, or question.
Vavuranakis et al. (2013) conducted an observational in Patent foramen ovale (n=25). Percutaneous closure of patent foramen ovale vs. Baseline (pre-procedure) was evaluated on Segmental left atrial function (strain rate, strain, and active emptying fraction). Percutaneous PFO closure transiently altered segmental left atrial function at 3 months, including decreased anterior wall strain rate, which reversed at 6 months.