Key result
Novel mapping identifies true AF sources in only ~54% of patients with repetitive patterns.
Why the study?
Repetitive focal and rotational activation patterns are used as ablation targets for AF, but evidence is lacking that all detected targets are actual AF sources.
Does a novel mapping approach based on repetitiveness and entrainment capability identify probable sources of atrial fibrillation?
Observational (n=13)
Does a novel mapping approach based on repetitiveness and entrainment capability identify probable sources of atrial fibrillation?
A novel mapping technique incorporating both repetitiveness and entrainment capability demonstrates that only a minority of focal or rotational patterns are likely to serve as true sources of atrial fibrillation.
Answers are grounded in this paper and cite their sources.
May warrant caution targeting repetitive AF patterns; leaves open validation of this technique in prospective trials.
Introduction: Repetitive focal and rotational activation patterns are currently used as additional ablation targets for atrial fibrillation (AF). However, there is no evidence that all these detected targets are actual sources of AF. In this paper, we present an approach that detects and ranks AF activation patterns not only based on the degree of pattern repetitiveness but also on the extent to which they are able to entrain their vicinity. This new technique might enable selecting the site with the highest probability of being a source for AF. Methods: = 13, PentaRay catheter, 30s recordings). Repetitive focal and rotational activation patterns were detected based on local activation time annotation of unipolar electrograms. The spatial stability was determined as local repetitive pattern duration. The entrainment capability was defined as the average time a directionally coherent repetitive activation pattern was observed in adjacent recordings. Results: test). By applying a 90th percentile threshold to both local and directionally coherent adjacent repetitiveness, we identified 10 sites (9 focal and 1 rotational) in 7 patients as the most probable sources. The majority of these sites were in the upper right atrium or left pulmonary vein region. Notably, in 6 patients (46 %), no probable sources were detected using this threshold. Conclusion: This study introduces a novel technique to select the repetitive focal or rotational pattern with the highest probability of being a source. We observed that only a minority of repetitive focal or rotational patterns seem to be able to entrain their vicinity and thereby are likely to serve as sources of AF.
No takes yet. Share an insight, caveat, or question.
Hermans et al. (2024) conducted an observational in Atrial fibrillation (n=13). Mapping technique based on repetitiveness and entrainment capability was evaluated on Identification of probable sources of AF. A novel mapping technique identified 10 probable AF source sites in 7 of 13 patients, showing that only a minority of repetitive focal or rotational patterns likely serve as actual sources of AF.
Synapse has enriched 10 related papers. Consider them for comparative context: