Key result
BIV pacing preserves superior synchrony over intrinsic rhythm in CRT super-responders, shortening QRS ~13 ms.
Why the study?
The extent of cardiac electrical and mechanical synchrony in super-responders to CRT and the necessity of continuous biventricular pacing remain unknown.
Does continuous biventricular pacing maintain better cardiac electrical and mechanical synchrony compared to intrinsic rhythm in CRT super-responders?
Cohort (n=17)
Yes
Does continuous biventricular pacing maintain better cardiac electrical and mechanical synchrony compared to intrinsic rhythm in CRT super-responders?
Even in CRT super-responders who normalize their ejection fraction, intrinsic electrical and mechanical synchrony remains inferior to biventricular pacing, suggesting continuous pacing should be maintained.
Answers are grounded in this paper and cite their sources.
SRs show improved but inferior intrinsic synchrony versus BIV pacing; leaves open whether continuous pacing can be safely discontinued.
BACKGROUND: Super-responders (SRs) to cardiac resynchronization therapy (CRT) regain near-normal or normal cardiac function. The extent of cardiac synchrony of SRs and whether continuous biventricular (BIV) pacing is needed remain unknown. The aim of this study was to evaluate the cardiac electrical and mechanical synchrony of SRs. METHODS: We retrospectively analyzed CRT recipients between 2008 and 2016 in 2 centers to identify SRs, whose left ventricular (LV) ejection fraction was increased to ≥50% at follow-up. Cardiac synchrony was evaluated in intrinsic and BIV-paced rhythms. Electrical synchrony was estimated by QRS duration and LV mechanical synchrony by single-photon emission computed tomography myocardial perfusion imaging. RESULTS: Seventeen SRs were included with LV ejection fraction increased from 33.0 ± 4.6% to 59.3 ± 6.3%. The intrinsic QRS duration after super-response was 148.8 ± 30.0 ms, significantly shorter than baseline (174.8 ± 11.9 ms, P = 0.004, t = -3.379) but longer than BIV-paced level (135.5 ± 16.7 ms, P = 0.042, t = 2.211). Intrinsic LV mechanical synchrony significantly improved after super-response (phase standard deviation [PSD], 51.1 ± 16.5° vs. 19.8 ± 8.1°, P < 0.001, t = 5.726; phase histogram bandwidth (PHB), 171.7 ± 64.2° vs. 60.5 ± 22.9°, P < 0.001, t = 5.376) but was inferior to BIV-paced synchrony (PSD, 19.8 ± 8.1° vs. 15.2 ± 6.4°, P = 0.005, t = 3.414; PHB, 60.5 ± 22.9° vs. 46.0 ± 16.3°, P = 0.009, t = 3.136). CONCLUSIONS: SRs had significant improvements in cardiac electrical and LV mechanical synchrony. Since intrinsic synchrony of SRs was still inferior to BIV-paced rhythm, continued BIV pacing is needed to maintain longstanding and synchronized contraction.
No takes yet. Share an insight, caveat, or question.
Li et al. (2019) conducted a cohort in Super-responders to cardiac resynchronization therapy (n=17). Biventricular (BIV) pacing vs. Intrinsic rhythm was evaluated on QRS duration (p=0.042). Biventricular pacing maintained superior electrical and mechanical synchrony compared to intrinsic rhythm in CRT super-responders.