Key result
Combined 2D and 3D ICUS identifies 90% of arterial dissections, outperforming standard 2D imaging.
Why the study?
The extent of vascular injury following PTCA is underestimated by angiographic assessment, and conventional ICUS requires mental reconstruction limiting accuracy.
Does combined two- and three-dimensional ICUS improve the accuracy of detecting and quantifying arterial dissection following PTCA compared to two-dimensional ICUS in atherosclerotic human coronary arteries?
Does combined two- and three-dimensional ICUS improve the accuracy of detecting and quantifying arterial dissection following PTCA compared to two-dimensional ICUS in atherosclerotic human coronary arteries?
Answers are grounded in this paper and cite their sources.
Combined two- and three-dimensional intracoronary ultrasound provides more accurate detection and quantification of arterial dissection following balloon angioplasty compared to conventional two-dimensional imaging in an ex vivo model.
BACKGROUND: Following percutaneous transluminal coronary angioplasty (PTCA), the extent of vascular injury is underestimated by angiographic assessment. Conventional intracoronary ultrasound (ICUS) imaging provides additional information with regard to the extent of dissections but requires mental reconstruction of consecutive images. Three-dimensional ICUS reconstruction overcomes this limitation and may provide more accurate assessment of the extent of vascular injury. This study compares conventional two-dimensional ICUS imaging to combined two- and three-dimensional ICUS information in the assessment of vascular injury following PTCA. METHODS: Atherosclerotic, human coronary arteries (n=24) were studied in a specially constructed flow system. Balloon dilatation of significant stenoses was performed followed by assessment using two- and three-dimensional ICUS imaging methods. Treated arteries were submitted for histological assessment after pressure fixation. Dissection depth and length measurements were made from obtained images and compared to histomorphometric assessments. RESULTS: Of the 20 arterial segments confirmed histologically to contain dissection, 11 (55%) and 18 (90%) were identified by two-dimensional ICUS and combined two- and three-dimensional ICUS respectively. The kappa values for correlation of dissection type were 0.29 (0.23-0.35) and 0.64 (0.57-0.71) respectively indicating better agreement using combined two- and three-dimensional ICUS. Two-dimensional ICUS consistently underestimated dissection length (3.52+/-1.75 mm compared with 6.54+/-2.42 mm, P<0.001) and depth (0.61+/-0.24 mm compared with 0.92+/-0.32 mm, P=0.001). Combined two- and three-dimensional ICUS produced accurate dissection length (6.13+/-2.29 mm compared with 6.54+/-2.42 mm, P=0.09) and depth (0.86+/-0.32 mm compared with 0.92+/-0.32 mm, P=0.28) estimations. CONCLUSION: Computerized three-dimensional reconstruction of ICUS images provides improved accuracy compared to conventional ICUS imaging in the detection and quantitation of arterial dissection. This technique would be a useful adjunct to angiography for the precise assessment of vascular injury following PTCA.
No takes yet. Share an insight, caveat, or question.
Palmer et al. (2003) studied Atherosclerotic coronary arteries following PTCA (n=24). Combined two- and three-dimensional intracoronary ultrasound (ICUS) vs. Conventional two-dimensional ICUS was evaluated on Identification of histologically confirmed arterial dissection. Combined two- and three-dimensional ICUS identified 90% of histologically confirmed dissections compared to 55% with two-dimensional ICUS, improving the accuracy of vascular injury assessment.