Key result
Late-phase prone CT detects intracardiac thrombi with ~90% sensitivity versus intracardiac echocardiography.
Why the study?
The accuracy of late-phase prone-position contrast CT for detecting intracardiac thrombi in patients with persistent or long-standing persistent AF before catheter ablation was not established.
Does late-phase prone-position contrast CT accurately detect intracardiac thrombi in patients with persistent or long-standing persistent AF before catheter ablation?
Observational (n=300)
Does late-phase prone-position contrast CT accurately detect intracardiac thrombi in patients with persistent or long-standing persistent AF before catheter ablation?
Effect estimate: sensitivity 0.900, specificity 0.621
Late-phase prone-position contrast CT is an accurate non-invasive tool for detecting intracardiac thrombi and assessing LAA dysfunction prior to AF ablation.
May support prone-position CT for pre-AF ablation thrombus screening; leaves open prospective validation against TEE before practice change.
Background: Contrast computed tomography (CT) is a useful tool for the detection of intracardiac thrombi. We aimed to assess the accuracy of the late-phase prone-position contrast CT (late-pCT) for thrombus detection in patients with persistent or long-standing persistent atrial fibrillation (AF). Methods: Early and late-phase pCT were performed in 300 patients with persistent or long-standing AF. If late-pCT did not show an intracardiac contrast defect (CD), catheter ablation (CA) was performed. Immediately prior to CA, intracardiac echocardiography (ICE) from the left atrium was performed to confirm thrombus absence and the estimation of the blood velocity of the left atrial appendage (LAA). For patients with CDs on late-pCT, CA performance was delayed, and late-pCT was performed again after several months following oral anticoagulant alterations or dosage increases. Results: Of the 40 patients who exhibited CDs in the early phase of pCT, six showed persistent CDs on late-pCT. In the remaining 294 patients without CDs on late-pCT, the absence of a thrombus was confirmed by ICE during CA. In all six patients with CD-positivity on late-pCT, the CDs vanished under the same CT conditions after subsequent anticoagulation therapy, and CA was successfully performed. Furthermore, the presence of residual contrast medium in the LAA on late-pCT suggested a decreased blood velocity in the LAA (≤ 15 cm/s) (sensitivity = 0.900 and specificity = 0.621). Conclusions: Late-pCT is a valuable tool for the assessment of intracardiac thrombi and LAA dysfunction in patients with persistent or long-standing persistent AF before CA.
No takes yet. Share an insight, caveat, or question.
Nakamura et al. (2021) conducted an observational in Persistent or long-standing persistent atrial fibrillation (n=300). Late-phase prone-position contrast CT (late-pCT) vs. Intracardiac echocardiography (ICE) was evaluated on Detection of intracardiac thrombi and decreased blood velocity in the left atrial appendage (sensitivity 0.900, specificity 0.621). Late-phase prone-position contrast CT accurately detected intracardiac thrombi and identified decreased left atrial appendage blood velocity with a sensitivity of 0.900 and specificity of 0.621.