Key result
Off-pump CABG with skeletonized gastroepiploic artery is associated with 0% early adverse events.
Why the study?
Vasospasm is a problem when using the gastroepiploic artery for coronary artery bypass grafting, and a skeletonized harvesting technique was used to minimize it.
Observational (n=25)
Skeletonized harvesting of the gastroepiploic artery for off-pump CABG appears safe and feasible, with excellent early clinical outcomes and no perioperative complications in a small pilot cohort.
Answers are grounded in this paper and cite their sources.
Skeletonized GEA harvesting may reduce vasospasm in off-pump CABG; leaves open efficacy and safety in larger trials.
Background: The problem with using the gastroepiploic artery (GEA)for coronary artery bypass grafting (CABG) is vasospasm. To minimize vasospasm of the GEA, a skeletonized harvesting technique was used for GEA harvesting. We present the initial results of GEA grafting using this technique. Methods: Between September 1, 2002, and December 31, 2002, a total of 25 patients (21 men and 4 women, mean age 65.4 +/- 8.7 years) gave informed consent and underwent elective off-pump CABG using the skeletonized GEA. Skeletonization was completed using an ultrasonic scalpel (Harmonic scalpel, coagulating-scissors; Ethicon Endo-Surgery, Cincinnati, OH, USA). Follow-up data were available until August 31, 2003. Perioperative, early clinical, and follow-up results were analyzed. Results: There were no hospital deaths, perioperative myocardial infarctions, congestive heart failure, strokes, or renal failure. There were no abdominal complications. Follow-up data were available from all patients, with a mean follow-up of 0.8 +/- 0.1 years. There were no cardiac deaths or cardiac events. Conclusion: During our limited follow-up period, the early results of skeletonized GEA grafting were excellent, and cardiac events have been well controlled. Mid-term follow-up study and angiographic study are necessary to confirm our initial clinical outcome data.
No takes yet. Share an insight, caveat, or question.
Amano et al. (2005) conducted an observational in Coronary artery disease requiring CABG (n=25). Off-pump CABG using skeletonized gastroepiploic artery was evaluated on Perioperative and follow-up clinical events (hospital deaths, myocardial infarctions, congestive heart failure, strokes, renal failure, cardiac events). Off-pump CABG using a skeletonized gastroepiploic artery resulted in 0% hospital deaths, perioperative complications, or cardiac events over a mean follow-up of 0.8 years.
Synapse has enriched 10 related papers. Consider them for comparative context: