Key result
TEE outperforms TTE for distal coronary sinus visualization, identifying anatomy in 100% of patients.
Why the study?
The comparative effectiveness of transthoracic echocardiography and transesophageal echocardiography in evaluating the coronary sinus and its blood flow was unclear.
Does transesophageal echocardiography improve the evaluation of the coronary sinus and its blood flow compared to transthoracic echocardiography?
Observational (n=40)
Does transesophageal echocardiography improve the evaluation of the coronary sinus and its blood flow compared to transthoracic echocardiography?
TEE is superior to TTE for visualizing and measuring the coronary sinus and its blood flow velocity, though flow volume calculations may be inaccurate due to dynamic changes in cross-sectional area.
Answers are grounded in this paper and cite their sources.
TEE may aid coronary sinus assessment when TTE is inadequate; leaves open impact on outcomes or practice.
The purpose of this study was to compare transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) in the evaluation of the coronary sinus and its blood flow. Forty patients were studied by TTE and TEE. The distal coronary sinus and its right atrial communication could be identified in 21 of 40 by TTE, and in all patients by TEE. Coronary sinus diameter measurement at the right atrial communication was possible by TTE in 16 of 40, and in all patients by TEE (maximal diameter 6 to 14 mm, mean 9 +/- 2). Flow velocity measurement by pulsed Doppler was possible in 25 of 40 patients (63%) by TEE, and in none by TTE. The flow velocity pattern was similar to central vein flow velocity, with systolic and diastolic antegrade waves, and a small retrograde end diastolic wave. The coronary sinus cross-sectional area was measured in 5 patients by intravascular ultrasound. It varied in size and shape during the cardiac cycle, reaching a maximum (0.3 to 1.5 cm2) at end diastole, and decreasing by 40% to 70% at end systole. TEE is superior to TTE in the evaluation of the coronary sinus and its blood flow velocity. However, because of the variability in cross-sectional area size and shape, measurement of coronary sinus blood flow may be inaccurate.
No takes yet. Share an insight, caveat, or question.
Kronzon et al. (1995) reported an observational. Transesophageal echocardiography (TEE) vs. Transthoracic echocardiography (TTE) was evaluated on Identification of the distal coronary sinus and its right atrial communication. Transesophageal echocardiography was superior to transthoracic echocardiography for identifying the distal coronary sinus and measuring flow velocity.