Answers are grounded in this paper and cite their sources.
In this work, the load-dependent indentation response of as-built Inconel 718 produced by direct laser deposition was studied, followed by local mapping around a single surface-intersecting pore. A working load of 100 mN was selected because the indentation modulus approached a depth-independent plateau and the penetration depth was substantially larger than the measured surface roughness. At this load, the reference matrix response was HIT = 2.69 ± 0.26 GPa and EIT = 160 ± 11 GPa. An equivalent contact radius ac was calculated from the projected contact area, and pore-edge distance was normalized as ξ = s/ac. For the reference response, ac ≈ 3.44 µm and the first numerically defined position at s = 20 µm corresponded to ξ ≈ 5.8. Robust regression of 56 individual measurements showed no statistically resolved dependence of EIT on ξ, whereas a small negative HIT slope was observed and interpreted cautiously because of directional variability. The analysis is restricted to this single pore and to ξ ≥ 5.8; the immediate pore-edge regime was not experimentally resolved. The contact-scale normalization provides a reproducible framework for interpreting local indentation data near a geometrical defect without treating the two-dimensional pore-area fraction as bulk porosity.
No takes yet. Share an insight, caveat, or question.
Doronin et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: