Key result
High-resolution ultrasound of carotid intima thickness accurately identifies endothelial cell dysfunction with ~0.90 AUC.
Why the study?
The association between carotid intima thickness measured by high-resolution ultrasound and endothelial cell dysfunction for early atherosclerosis risk assessment was evaluated.
Does carotid intima thickness assessed by high-resolution ultrasound correlate with endothelial cell dysfunction in middle-aged nonsmoking adults?
Cross-Sectional (n=66)
Does carotid intima thickness assessed by high-resolution ultrasound correlate with endothelial cell dysfunction in middle-aged nonsmoking adults?
Effect estimate: AUC 0.896
p-value: p=<0.001
High-resolution ultrasound measurement of carotid intima thickness serves as a strong noninvasive imaging marker of early endothelial dysfunction.
May support noninvasive cIT for endothelial dysfunction detection; hypothesis-generating and requires prospective validation.
Purpose This study evaluated the association between carotid intima thickness (cIT), measured using high-resolution ultrasound, and endothelial cell dysfunction (ECD), assessed using flow-mediated dilation (FMD), for early atherosclerosis risk assessment. Methods Between January and December 2024, 102 middle-aged nonsmoking participants were prospectively recruited; 66 were included in the final analysis and classified into a risk group (n=44) or control group (n=22) according to the presence or absence of at least one conventional cardiovascular risk factor. Data collected included demographic characteristics, physical measurements, laboratory findings, cIT, carotid media thickness (cMT), and carotid intima-media thickness (cIMT). After 5 minutes of forearm occlusion, brachial artery diameters were measured at baseline and at 30, 60, and 120 seconds after cuff deflation during systole and diastole, and FMD indices were calculated. Receiver operating characteristic (ROC) curve analysis was performed, with differences between the ROC curves evaluated using the Hanley-McNeil test. Results Compared with the control group, the risk group had greater cIT (P<0.001) and cIMT (P=0.016) and generally lower FMD indices. cMT did not differ significantly between groups (P=0.595). Among carotid ultrasound parameters, cIT showed the strongest association with atherosclerosis risk (standardized β=0.489, P<0.05) and the strongest inverse correlation with systolic FMD measured 60 seconds after cuff deflation (FMD S60 ; ρ=−0.689, adjusted P=0.001). In ROC analysis, cIT generally showed better performance for identifying ECD than cMT and cIMT, with a maximum area under the curve of 0.896 (P<0.001). Conclusions High-resolution ultrasound measurement of cIT may provide a noninvasive imaging marker of early endothelial dysfunction.
No takes yet. Share an insight, caveat, or question.
Shen et al. (2026) conducted a cross-sectional in Endothelial cell dysfunction (n=66). Carotid intima thickness (cIT) vs. Carotid media thickness (cMT) and carotid intima-media thickness (cIMT) was evaluated on Identification of endothelial cell dysfunction (ECD) (AUC 0.896, p=<0.001). Carotid intima thickness measured by high-resolution ultrasound accurately identified endothelial cell dysfunction (AUC 0.896, P<0.001), outperforming other carotid ultrasound parameters.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: