Key result
Encoder-decoder model boosts ECG-to-text METEOR scores by ~127% over prior models on PTB-XL.
Why the study?
The field of free-text ECG report generation lacks a reproducible, leakage-safe evaluation protocol to enable comparable results across studies.
Introduces a reproducible, leakage-safe benchmark and reference implementation for ECG-to-text report generation, demonstrating improved METEOR scores over prior models.
Answers are grounded in this paper and cite their sources.
New leakage-safe benchmark yields higher ECG-to-text scores than prior reports; extends evaluation standards but leaves clinical adoption open.
Free-text report generation directly from ECG signals is an emerging task, but the field currently lacks a reproducible, leakage-safe evaluation protocol that makes results comparable across studies. To address this, we introduce both a benchmark and a reference implementation: the benchmark provides a leakage-safe evaluation protocol with concrete performance floors, and the reference implementation provides a tuned reference system that future ECG-to-text methods can be compared against. Our central contribution is the benchmark: an evaluation protocol on PTB-XL using the official, patient-exclusive splits, together with two architecture-agnostic statistical floors (a text-only lexical baseline and a class-conditional deterministic template baseline) and two model-dependent floors (a label-only neural baseline and a nearest-neighbor retrieval baseline) that quantify how much of a model’s score can be explained by report priors, rhythm-level shortcuts, and latent-space retrieval alone. We additionally include a random-split negative control that quantifies leakage-driven score inflation, and a stress test on a proprietary single-lead subcutaneous ECG dataset from implantable cardiac monitors, with analysis of site-level reporting bias. As the reference implementation, we adapt a standard encoder–decoder, image-captioning-style pipeline (ResNet encoder with LSTM or Transformer decoder) to signal-to-text on PTB-XL. Under this protocol, the reference implementation reaches METEOR 55.53% on PTB-XL, clearing all four floors; the primary prior model reported 24.51% under a leakage-prone random-split setup. We read these gains as improvements on this benchmark rather than evidence of clinically grounded morphological understanding: evaluation relies on lexical-overlap metrics over short, templated reports, and the margin over the strongest retrieval baseline is modest.
No takes yet. Share an insight, caveat, or question.
Bleich et al. (2026) studied ECG-to-text report generation. Encoder-decoder image-captioning-style pipeline vs. Baseline floors and prior models was evaluated on METEOR score. An encoder-decoder reference implementation achieved a METEOR score of 55.53% on the PTB-XL dataset, outperforming the primary prior model's 24.51% and clearing all baseline floors.
Synapse has enriched 10 related papers. Consider them for comparative context: