Key result
Arterial fluorescence spectral width correlates strongly with tissue collagen:elastin content.
Why the study?
Normal arteries have site-dependent variation in collagen:elastin content which may affect their fluorescence spectra, impacting laser ablation guidance.
Effect estimate: r = -0.84
p-value: p=<0.005
Arterial site influences fluorescence spectra; leaves open reliable fluorescence-guided laser ablation without site-specific calibration.
The difference in fluorescence between normal and atherosclerotic artery has been proposed as a feedback mechanism to guide selective laser ablation of atherosclerotic plaque. This fluorescence difference is due to the relative difference in collagen:elastin content of normal artery and atherosclerotic plaque. However, normal arteries have site-dependent variation in collagen: elastin content which may affect their fluorescence spectra. To evaluate the site dependency of normal arterial fluorescence, helium-cadmium (325 nm) laser-induced fluorescence spectra were analyzed in vitro from the ascending aorta, abdominal aorta, and carotid, femoral, renal, and coronary arteries (N = 57) of 12 normal mongrel dogs. Elastin and collagen contents were determined for a subset of these arteries (N = 15). The spectral width of normal arterial Fluorescence varied by site and correlated with the measured collagen:elastin content at each site (r = -0.84, P less than 0.005). Fluorescence spectra were decomposed into collagen and elastin spectral components by using a linear model with a least-squared error criterion fit. The derived collagen and elastin spectral coefficients correlated with the measured collagen and elastin tissue content (r = 0.75 and 0.83 respectively, P less than 0.005). Thus, the fluorescence spectra of normal arteries is site dependent and correlates with the collagen:elastin content. Therefore, spectral feedback algorithms for laser angioplasty guidance must be site specific.
No takes yet. Share an insight, caveat, or question.
Garrand et al. (1990) studied Normal arteries (site dependency of fluorescence) (n=12). Helium-cadmium (325 nm) laser-induced fluorescence was evaluated on Correlation between spectral width of normal arterial fluorescence and measured collagen:elastin content (r = -0.84, p=<0.005). The spectral width of normal arterial fluorescence varied by site and correlated significantly with the measured collagen:elastin content (r = -0.84, P < 0.005).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: