Key result
Peak flow triggered ASV improves composite clinical and patient-reported outcomes ~18% over standard care.
Why the study?
Conventional cardiovascular trials focus on morbid and mortal events, but incorporating symptom relief and quality of life endpoints can assess broader intervention effects in HFrEF patients with sleep apnea.
Does peak flow triggered adaptive servo-ventilation improve a hierarchical composite of clinical, symptomatic, and sleep outcomes in patients with HFrEF and sleep apnea?
RCT (n=731)
Randomized
Does peak flow triggered adaptive servo-ventilation improve a hierarchical composite of clinical, symptomatic, and sleep outcomes in patients with HFrEF and sleep apnea?
A win-ratio analysis incorporating clinical and patient-relevant endpoints suggests an overall treatment benefit of peak flow triggered adaptive servo-ventilation in HFrEF patients with sleep apnea.
Answers are grounded in this paper and cite their sources.
Win ratio analysis suggests possible ASV PF benefit on hierarchical outcomes including QoL in HFrEF with sleep apnea; leaves open need for prospective trials before practice change.
Background Conventionally, cardiovascular trials evaluate impact on morbid and mortal events. ‘Win ratio' analyses adding symptom relief and quality of life endpoints can assess broader intervention effects. Applying ‘win-ratio' principles, we conducted a post-hoc analysis of ADVENT-HF trial findings. Methods ADVENT-HF examined the impact of treating obstructive or central sleep apnea (OSA, CSA) using peak flow triggered adaptive servo-ventilation (ASV PF ) in patients with heart failure with reduced ejection fraction (HFrEF). After pre-randomization stratification into OSA (n=533) or CSA (n=198) cohorts, participants were randomly allocated to standard care (n=375) or standard care plus ASV PF (n=356). The following trial endpoints were compared over shared follow-up time of pairs of treated and control participants in a descending hierarchical order: 1) all-cause death; 2) cardiovascular hospitalizations; 3) improvement from baseline at 1 year, in 2 or more of the Epworth Sleepiness Scale, Minnesota Living with Heart Failure Quality of Life, or the NYHA class scores; 4) change from baseline in the sum of stage N3 and rapid eye movement (REM) sleep stage duration; and 5) change from baseline in arousals. Results The win ratio calculated on sequential addition of outcomes to the hierarchy was 1.18 (1.00-1.39). The win difference was 7.6%. The principal contributions to the latter were quality of life (4.2%) and time in stage 3 plus REM sleep (2.1%). Ranking quality of life second increased the win ratio to 1.22 (1.04-1.43) and the win difference to 9.1%. Conclusions A win-ratio analysis incorporating ADVENT-HF clinical and patient-relevant endpoints favors overall ASV PF treatment benefit. ASV PF appeared more effective in the CSA cohort with respect to adherence, sleep structure and quality of life. (NCT01128816).
No takes yet. Share an insight, caveat, or question.
Floras et al. (2026) conducted an RCT in Heart failure with reduced ejection fraction and sleep apnea (n=731). Peak flow triggered adaptive servo-ventilation (ASV PF) vs. Standard care was evaluated on Hierarchical composite of all-cause death, cardiovascular hospitalizations, improvement in QoL/symptoms, and changes in sleep structure/arousals (Win ratio 1.18, 95% CI 1.00-1.39). Peak flow triggered adaptive servo-ventilation improved a hierarchical composite of clinical and patient-relevant outcomes compared to standard care.