Key result
Advanced fluoroscopic image processing linked to ~28 Gy·cm² lower radiation dose during TAVI.
Why the study?
Radiation exposure during transcatheter aortic valve implantation is a concern for patients and operators, warranting efforts to reduce radiation dose.
Observational (n=152)
No
Mean Difference: -27.5 (95% CI 15.9–39.1)
p-value: p=<0.001
Advanced image processing was associated with lower radiation in TAVI; leaves open whether it improves outcomes or should change practice.
OBJECTIVES: Radiation exposure is a concern for both patients and operators during transcatheter aortic valve implantation (TAVI). Efforts to reduce radiation dose are warranted. We aimed at investigating if per-operative advanced image processing can reduce patient and operator irradiation use during TAVI. METHODS: We performed a prospective single-centre observational study comparing patient and operator radiation exposure using standard fluoroscopy (control group) or a novel technology of live advanced fluoroscopic image processing (test group) among consecutive patients undergoing TAVI between August 2015 and April 2016. Patient irradiation (dose-area product, effective dose and air kerma), contrast media volume and clinical outcomes were assessed. RESULTS: Among 152 elderly [median age (interquartile range): 83 (78-87)] patients (n = 76 per group) undergoing TAVI, baseline clinical characteristics were similar between the control and test groups, except for a higher median EuroSCORE II (2.8% vs 2.3%, P = 0.02) and higher rate of TAVI for failing surgical bioprosthesis (11.8% vs 2.6%, P = 0.03) in the control group. The dose-area product was reduced in the test group: mean reduction of -27.5 Gy × cm2 [95% confidence intervals (CIs): 15.9-39.1, P < 0.001]. Furthermore, effective dose [mean reduction -6.5 (95% CI: 5.9-7.2) mSv, P < 0.001] and air kerma [mean reduction -167.5 (95% CI 163.4-177.3) mGy, P < 0.001] were lower in the test group. Fluoroscopy time, contrast volume and clinical outcomes were similar. CONCLUSIONS: Patient radiation exposure was significantly reduced using a novel live advanced fluoroscopy image processing with calcification enhancement and fusion of the virtual aortic annulus without compromising patient safety.
No takes yet. Share an insight, caveat, or question.
Overtchouk et al. (2018) conducted an observational in Transcatheter aortic valve implantation (TAVI) (n=152). Live advanced fluoroscopic image processing vs. Standard fluoroscopy was evaluated on Dose-area product (mean reduction -27.5, 95% CI 15.9-39.1, p=<0.001). Live advanced fluoroscopic image processing significantly reduced patient dose-area product compared to standard fluoroscopy during TAVI (mean reduction -27.5 Gy × cm2; 95% CI 15.9-39.1; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: