Key result
Urografin 60% linked to marked transient ECG changes vs Ringer solution during coronary angiography.
Why the study?
The ECG changes induced by selective coronary angiography contrast injection and their underlying mechanisms were not fully characterized.
Observational (n=95)
Answers are grounded in this paper and cite their sources.
Urografin may induce transient ECG changes during angiography; leaves open relevance to modern agents and clinical outcomes.
During selective coronary angiography ECG was recorded in leads 1 and II in 95 consecutive patients with the purpose of studying the ECG changes invoked by the injection of 7 ml Urografin 60% (Schering). Marked but transient changes were seen, probably caused by the physico‐chemical properties of the contrast medium. The selective injection of the same volume of Ringer solution did not evoke any ECG changes. When a blood volume in the coronary circulation is replaced by contrast medium or Ringer solution, transient coronary hypoxia will result. This hypoxia, therefore, is not the cause of the ECG changes observed in coronary angiography. Selective coronary angiography appears to impair depolarization as well as repolarization, the latter being the most affected function. Absence of ECG response during coronary injections indicates severe coronary artery disease or the presence of a single coronary artery. Right coronary injection is followed by an increase in PQ interval; arrhythmias seldom occur but are more likely to appear during right than during left coronary injections. The changes observed in this series are increased QRS and QT duration, a shift in QRS axis in the frontal plane, which is clockwise during right and counter‐clockwise during left coronary injections. The QRS vector is doubled. The T axis rotates in the frontal plane towards + 120° during left and towards – 75° during right coronary injection. When the T axis has this direction before angiography, no shift in axis is seen during injection of contrast medium.
No takes yet. Share an insight, caveat, or question.
Grendahl et al. (1972) conducted an observational in Patients undergoing selective coronary angiography (n=95). Injection of Urografin 60% vs. Ringer solution was evaluated on ECG changes. Injection of Urografin 60% during coronary angiography caused marked transient ECG changes, including increased QRS and QT duration and axis shifts, which were not seen with Ringer solution.
Synapse has enriched 10 related papers. Consider them for comparative context: