Key result
Integrated ultrasonic backscatter is ~6.5 dB higher in the RV than LV but lacks collagen correlation.
Why the study?
The relationship between integrated ultrasonic backscatter and collagen content in normal ventricular myocardium was unclear, including the effect of formalin fixation on backscatter.
Absolute Event Rate: -60.4% vs -66.9%
p-value: p=<.001
RV shows higher backscatter than LV in normal hearts; leaves open its role for detecting fibrosis in patients.
Integrated ultrasonic backscatter has been related to collagen deposition in fibrotic myocardium. The purpose of our study was to measure the integrated ultrasonic backscatter in the right and left ventricles of 10 normal freshly excised canine hearts and five normal formalin-fixed human hearts. A 2.25 MHz, 50% fractional bandwidth transducer was positioned at the transducer focal distance from the epicardium. The radio frequency backscatter signal, excluding specular reflections, was digitized, squared, and integrated to yield the integrated ultrasonic backscatter (in decibels down from a 100% reflector). The segment of myocardium corresponding to the integrated ultrasonic backscatter sample volume was excised and assayed for hydroxyproline, a marker for collagen. A second purpose of our study was to evaluate the influence of fixation with formalin on the backscatter. Regional integrated ultrasonic backscatter was therefore measured in 10 freshly excised canine left ventricles, which were fixed in 10% formalin for 2 weeks. Integrated ultrasonic backscatter measurements were then repeated. In freshly excised canine hearts, the integrated ultrasonic backscatter from right ventricle was higher than that from left ventricle (-60.4 +/- 1.6 [SEM] vs -66.9 +/- 1.0 dB; p less than .001). The collagen content of right ventricle was also higher than that of left ventricle (4.40 +/- 0.26 [SEM] vs 3.58 +/- 0.13 micrograms/mg dry weight; p less than .005). Similar results were obtained in human hearts. There were no correlations between integrated ultrasonic backscatter and collagen content (r = .28 and .32 for dogs and humans, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Skorton et al. (1984) studied Normal ventricular myocardium (n=15). Right ventricle vs. Left ventricle was evaluated on Integrated ultrasonic backscatter (p=<.001). Integrated ultrasonic backscatter was higher in the right ventricle compared to the left ventricle (-60.4 vs -66.9 dB; p<0.001), but showed no correlation with collagen content.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: