Key result
Preoperative pulse rate variability fails to predict hemodynamic response to tracheal intubation.
Why the study?
Individual hemodynamic responses to tracheal intubation vary considerably, and the association with preoperative pulse rate variability is unclear.
Does preoperative pulse rate variability predict the hemodynamic response to tracheal intubation in adults undergoing elective surgery under general anesthesia?
Cohort (n=183)
No
Does preoperative pulse rate variability predict the hemodynamic response to tracheal intubation in adults undergoing elective surgery under general anesthesia?
Preoperative pulse rate variability derived from a short photoplethysmogram does not reliably identify patients at risk of a hemodynamic response to tracheal intubation.
Answers are grounded in this paper and cite their sources.
Preoperative PRV should not guide intubation response prediction; leaves open whether refined indices merit prospective validation.
Individual hemodynamic responses to tracheal intubation vary considerably. We examined whether preoperative pulse rate variability (PRV), a photoplethysmography-derived surrogate of heart rate variability, is associated with this response. In this retrospective secondary analysis, 183 adults undergoing elective surgery under general anesthesia were analyzed. A 3-min photoplethysmogram was recorded in the supine, resting, unsedated state immediately before induction, and time-domain (mean pulse-to-pulse interval [mean PPI], RMSSD, and pNN50) and frequency-domain (LF power, HF power, and LF/HF) PRV indices were computed. A hemodynamic response was defined as a systolic blood pressure rise >15 mmHg, or a heart rate rise to >90 beats/min or by >30% (≥ 10% if baseline ≥90 beats/min); patients were classified as response-present or response-absent. Of 183 patients, 101 (55.2%) were response-present and 82 (44.8%) response-absent. LF/HF was higher in the response-present group (1.84 [1.32–2.60] vs 1.37 [0.78–2.44]; unadjusted P = 0.018), but no index remained significant after correction for multiple comparisons (LF/HF adjusted P = 0.109; all others adjusted P ≥ 0.301). Discrimination was limited (AUC 0.602; 95% CI 0.518–0.684). In a sensitivity analysis using a blood-pressure-only response definition, no PRV index differed significantly. After correction for multiple comparisons, no preoperative PRV index differed significantly between patients with and without a hemodynamic response to tracheal intubation. LF/HF was higher in the response-present group before correction, but the effect size was small and the discriminative performance limited. These findings do not support preoperative PRV for identifying patients at risk and are hypothesis-generating only. Trial Registration number : KCT0005840.
No takes yet. Share an insight, caveat, or question.
Ryu et al. (2026) conducted a cohort in Elective surgery under general anesthesia (n=183). Preoperative pulse rate variability (PRV) was evaluated on Hemodynamic response to tracheal intubation (systolic blood pressure rise >15 mmHg, or heart rate rise to >90 beats/min or by >30%) (AUC 0.602 for LF/HF, 95% CI 0.518-0.684, p=0.109). Preoperative pulse rate variability indices, including the LF/HF ratio, did not significantly predict a hemodynamic response to tracheal intubation after correction for multiple comparisons.