Key result
Concomitant TVr during LVAD implantation linked to ~90% lower mortality vs LVAD alone.
Why the study?
The impact of tricuspid valve repair at the time of LVAD implantation on survival and right ventricular failure outcomes was unclear.
Cohort (n=101)
No
Hazard Ratio: 0.1
Absolute Event Rate: 92.9% vs 87.4%
p-value: p=0.049
May support concomitant tricuspid repair for LVAD survival benefit; hypothesis-generating and should not change practice without prospective confirmation.
PURPOSE: Tricuspid regurgitation contributes to right ventricular failure (RVF) and is associated with worse clinical outcomes in patients undergoing left ventricular assist device (LVAD) treatment. However, whether tricuspid valve repair (TVR) at the time of LVAD implantation improves outcomes is not clear. METHODS: We identified all patients undergoing initial implantation of a long-term continuous-flow LVAD at our institution from March 2006 to August 2011. We assessed the impact of TVR on survival and incidence of RVF using Kaplan-Meier curves and proportional hazards regression adjusted for age, gender, baseline tricuspid regurgitation, RV function, MELD score, albumin, and indication (bridge vs. destination). RESULTS: A total of 101 patients were included in the analysis, of which 14 patients underwent TVR concomitant LVAD. All TVR patients had moderate or severe baseline regurgitation. Crude survival was not different between groups. In multivariable models adjusted for confounding factors, TVR showed a significant association with improved survival (HR = 0.1, p = 0.049). Adjusted models showed no difference in RVF. CONCLUSIONS: In this cohort of patients, TVR at the time of LVAD implantation appears associated with better survival. Additional larger studies are needed to verify the effect of TVR at the time of LVAD implantation, and whether it should be utilized more frequently.
No takes yet. Share an insight, caveat, or question.
Brewer et al. (2014) conducted a cohort in End-stage heart failure (n=101). Concomitant tricuspid valve repair vs. Left ventricular assist device implantation alone was evaluated on Survival (HR 0.1, p=0.049). Concomitant tricuspid valve repair during left ventricular assist device implantation was significantly associated with improved survival compared to LVAD implantation alone (adjusted HR 0.1, p=0.049).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: