Key result
Mild aortic insufficiency repair during CF-LVAD implantation linked to ~82% 2-year freedom from worsening regurgitation.
Why the study?
Management of pre-existing mild aortic insufficiency in patients undergoing continuous-flow left ventricular assist device implantation is unknown.
Cohort (n=56)
Answers are grounded in this paper and cite their sources.
Concomitant repair may curb AI progression in LVAD patients with mild AI and large aortic roots; leaves open whether routine repair improves survival or should change practice.
OBJECTIVES: Aortic insufficiency (AI) after continuous-flow left ventricular assist device (CF-LVAD) implantation has become a highly relevant subject. However, management of pre-existing mild AI is unknown. We examined the fate of pre-existing mild AI during CF-LVAD support. METHODS: From March 2004 to October 2015, 446 consecutive patients received CF-LVAD. Of these, 56 (12.6%) patients with pre-existing mild AI were identified. Outcomes were compared between patients who underwent repair [n = 41 (73.2%); Group A] and those who did not [n = 15 (26.8%); Group B]. RESULTS: Group A patients were more likely to have destination therapy intent at device insertion than Group B. Otherwise both groups displayed similar clinical/echocardiographic findings at baseline. There was no difference with respect to the occurrence of postoperative adverse events between groups. Kaplan-Meier analyses revealed the estimated 2-year on-device survival to be 63.3 ± 10.7 and 84.0 ± 10.6% (P = 0.41) and freedom from AI ≥moderate at 2 years to be 81.8 ± 9.7 and 45.0 ± 21.1% (P = 0.031) in Groups A and B, respectively. Furthermore, 83.3% (5 of 6) of Group B patients with large (>1.94 cm/m2; 75th percentile) body surface area-indexed aortic diameter developed ≥moderate AI, while none of the Group B individuals with smaller aortic root (0 of 9) did. In contrast, Group A patients with large indexed aortic root (n = 7) have all been free of AI at 2 years. CONCLUSIONS: AI progression among CF-LVAD-supported patients with baseline mild AI is highly prevalent. Baseline aortic root diameter may help identify patients with 'borderline' AI lesion needing repair at device insertion.
No takes yet. Share an insight, caveat, or question.
Fukuhara et al. (2017) conducted a cohort in Mild aortic insufficiency during continuous-flow left ventricular assist device (CF-LVAD) implantation (n=56). Concomitant repair of mild aortic insufficiency vs. No repair was evaluated on Freedom from aortic insufficiency ≥moderate at 2 years (p=0.031). Concomitant repair of mild aortic insufficiency during CF-LVAD implantation increased 2-year freedom from moderate or worse aortic insufficiency compared to no repair.
Synapse has enriched 10 related papers. Consider them for comparative context: