Answers are grounded in this paper and cite their sources.
The operating conditions (relative humidity) of a fuel cell are not ideal, and directly influence performance. A high relative humidity of fuel facilitates flooding with water downstream in the fuel cell, worsening its performance. In this study, a flexible micro humidity sensor is fabricated on a stainless steel foil using micro-electro-mechanical systems (MEMS). It has the advantages of high temperature resistance, small size, high sensitivity, and precision of measurement position. Flexible micro humidity sensors are embedded in a proton exchange membrane fuel cell (PEMFC). Experimental results obtained at a high current density and relative humidities of 100% and 75% demonstrate that the relative humidity midstream and downstream saturated, because of serious flooding by water.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2012) studied this question.