Answers are grounded in this paper and cite their sources.
Conventional DC PCT (power cycling test) is simple and repeatable, but they cannot reproduce T j (junction temperature) trajectory generated by converter operation. This paper proposes a novel PCT method for reproducing application relevant T j waveform characteristics while maintaining a simple test circuit and compatibility with V CE ( T ) based temperature monitoring. Taking an IGBT module in a three-phase SPWM inverter as an example, the operating T j waveform is analyzed from conduction loss, switching loss, and thermal-network response. The results show that T j contains a dominant low frequency swing related to the output frequency of converter and a smaller high frequency swing related to the switching frequency of converter. A test circuit and control timing strategy are then developed to map these waveform quantities to controllable test parameters. PLECS electro-thermal simulation verifies that the proposed method can reproduce the main T j waveform characteristics. Long term power cycling tests and failure mode comparison will be conducted in future work.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: