Answers are grounded in this paper and cite their sources.
Aim: The purpose of this study was to evaluate the effect of taper on retention of copings in straight and angled implant abutment. Materials and Methods: Totally, 10 straight abutments (Adin Israel) of 3° taper and angled abutment of 15° taper with their analogs were used. Twenty castings were fabricated on the abutment that incorporated an attachment to allow removal. Castings were cemented to abutments with provicol (VOCO Germany). A uniaxial tensile force was applied to the crown using an instron machine until cement failure occurred. Results: Data were subjected to Shapiro-Wilk test, and it was found that variables have a normal distribution. Hence, Student's t-test was performed, and P value was found to be 0.00 <0.05. Hence to infer significant statistical difference.Conclusion: The retention of straight abutments was significantly more when compared to angled abutment when cemented with provicol. When using angled abutment, permanent luting agent should be the choice for cementation.
No takes yet. Share an insight, caveat, or question.
Meshramkar et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: