Key result
Angio-IMR methods fail to accurately identify coronary microvascular dysfunction compared with invasive PW-IMR.
Why the study?
Established indices for assessing coronary microvascular dysfunction such as PW-IMR and Rmicro remain underutilized, prompting development of wire-free angiography-derived IMR methods.
Do angiography-derived IMR (angio-IMR) methods accurately predict invasive pressure-wire IMR (PW-IMR) and absolute microvascular resistance (Rmicro) in patients with ANOCA or prior STEMI?
Observational (n=305)
Blinded analysts
Yes
Do angiography-derived IMR (angio-IMR) methods accurately predict invasive pressure-wire IMR (PW-IMR) and absolute microvascular resistance (Rmicro) in patients with ANOCA or prior STEMI?
All five tested angiography-derived IMR methods demonstrated poor diagnostic accuracy compared to invasive reference standards, highlighting significant limitations for their routine clinical adoption.
Answers are grounded in this paper and cite their sources.
Angio-IMR methods should not yet replace invasive PW-IMR; leaves open refinement and prospective validation of angiography-based microvascular indices.
BACKGROUND Coronary microvascular dysfunction should be assessed in patients with angina and non-obstructive coronary artery disease. However, established indices such as the pressure-wire-derived index of microvascular resistance (PW-IMR) and continuous thermodilution-derived absolute hyperemic microvascular resistance (Rmicro) remain underutilized, driving development of the wire-free angiography-derived IMR (Angio-IMR). OBJECTIVES Core lab comparison of five Angio-IMR methods. METHODS Five angio-IMR methods derived from three software platforms (QAngio XA 3D, FlashAngio, and AngioPlus Core) were compared against PW-IMR in 270 patients (274 vessels) and Rmicro in 42 patients (109 vessels) in a blinded fashion. Diagnostic performance was assessed on a per-vessel basis using receiver-operating characteristic (ROC) curves, Bland-Altman plots, and confusion matrices. RESULTS The median (IQR) PW-IMR was 19.02[12.79-28.08] with 81/274 (29.6%) vessels having a PW-IMR≥25. The median Rmicro was 387.50[312.00-501.00] with 33/109 (30.3%) vessels having an Rmicro≥475 Woods units (WU). The correlations between angio-IMR, PW-IMR, and Rmicro were poor across all methods. Three of the five methodologies overestimated PW-IMR (mean biases -20.72 to -26.36), with all exhibiting large random errors. ROC analysis using angio-IMR for discriminating PW-IMR≥25 showed area under the ROC curve (AUC) ranging from 0.530 to 0.576 (p>0.05 for all), while three methods (A, B, D) showed significantly better AUCs to discriminate Rmicro≥475 WU. When using the pre-specified angio-IMR≥25 threshold, only method E demonstrated acceptable accuracies of 61.4% and 62.0% to identify a PW-IMR≥25 and Rmicro≥475WU, respectively. CONCLUSION All five angio-IMR methods demonstrated poor diagnostic accuracy compared to PW-IMR and Rmicro, highlighting significant limitations in their clinical utility.
No takes yet. Share an insight, caveat, or question.
Tsai et al. (2025) conducted an observational in Angina with nonobstructive coronary arteries (ANOCA) or prior STEMI (n=305). Angiography-derived index of microvascular resistance (angio-IMR) methods vs. Invasive pressure-wire IMR (PW-IMR) and continuous thermodilution-derived absolute microvascular resistance (Rmicro) was evaluated on Discrimination of PW-IMR ≥25 (AUC 0.530-0.576, p=>0.05). All 5 angiography-derived index of microvascular resistance (angio-IMR) methods demonstrated poor diagnostic accuracy compared with invasive PW-IMR, with areas under the ROC curve ranging from 0.530 to 0.576 for discriminating PW-IMR ≥25.
Synapse has enriched 10 related papers. Consider them for comparative context: