Key result
Trans-device pulsed-field ablation maintains sinus rhythm at ~20 months despite a large ASD occluder.
Why the study?
Pulsed-field ablation across a large atrial septal defect closure device in patients with complex septal anatomy requires evaluation for safety and long-term efficacy.
Case Report (n=1)
No
Balloon-assisted transseptal puncture across a large ASD closure device can safely enable pulsed-field ablation in complex septal anatomies, providing durable sinus rhythm and symptom relief.
Answers are grounded in this paper and cite their sources.
May support balloon-assisted transseptal PFA across ASD occluders; hypothesis-generating and requires validation in larger cohorts.
Balloon-assisted transseptal puncture across a large atrial septal defect closure device can permit pulsed-field ablation in selected patients with complex septal anatomy, achieving durable pulmonary vein isolation and sinus rhythm. A borderline residual left-to-right shunt developed post-procedure but decreased on serial imaging without hemodynamic consequence.
No takes yet. Share an insight, caveat, or question.
Abdelrazik et al. (2026) conducted a case report in Atrial fibrillation with atrial septal defect closure device (n=1). Pulsed-field ablation with balloon-assisted transseptal access was evaluated on Restoration and maintenance of sinus rhythm. Pulsed-field ablation delivered via balloon-assisted transseptal access successfully restored and maintained sinus rhythm over 20 months in a patient with a large ASD closure device.