Key result
Complete coronary occlusion produces ST elevation in ~68% of patients within 50 seconds.
Why the study?
Does complete acute coronary occlusion produce electrocardiographic ischemic findings within seconds rather than minutes to hours in patients undergoing elective angioplasty?
Does complete acute coronary occlusion produce electrocardiographic ischemic findings within seconds rather than minutes to hours in patients undergoing elective angioplasty?
p-value: p=<.001
Ischemic electrocardiographic changes begin within seconds of abrupt complete coronary occlusion, refuting conventional teaching that dictates a latency of minutes to hours.
Prompts earlier ECG review in suspected occlusion; challenges teaching yet leaves open practice change in spontaneous ACS.
Conventional teaching describes a fixed sequence: hyperacute T waves within minutes, ST-segment elevation at approximately 30 min, and pathologic Q waves over hours. No primary study reports that interval; experimental occlusion places ST elevation within 25 to 40 s of ligation. In STAFF III (104 patients, 142 recordings), balloon inflation during elective angioplasty produces complete occlusion with the onset recorded to the second. Three criteria were applied to 10-s windows on a 5-s grid: guideline ST-elevation cutoffs at the J point relative to the PQ junction, the Meyers hyperacute T-wave score, and the Birnbaum terminal QRS distortion definition referred to each patient's own baseline. In leads subtending the occluded artery, ST-segment displacement and the hyperacute T-wave score both exceeded resting variability within 15 s and rose faster during occlusion than at rest (P < .001). Criteria were satisfied within 1 to 2 min: ST elevation in 71 of 104 patients (68%) at 50 s, terminal QRS distortion in 24 (23%) at 80 s, and hyperacute T waves in 16 (15%) at 70 s. Q waves could not be resolved. After deflation, Wellens type A predominated in anterior leads (6.2% vs 1.3% of other leads; P = .001), whereas type B did not. Ischemic electrocardiographic change begins within seconds of abrupt complete occlusion, with the T wave and the ST segment affected together. The traditional interval reflects the intermittent, incomplete occlusion of spontaneous infarction and clinical sampling intervals, rather than any latency in the myocardial response.
No takes yet. Share an insight, caveat, or question.
Alencar et al. (2026) studied Acute coronary occlusion (elective angioplasty model) (n=104). Balloon inflation (complete coronary occlusion) vs. Patient's own baseline (rest) was evaluated on Time to electrocardiographic ischemic findings (ST elevation) (p=<.001). Complete coronary occlusion by balloon inflation produced ST elevation in 68% of patients at 50 seconds, demonstrating that ischemic electrocardiographic changes begin within seconds.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: