Key result
Emergent MCS during TAVR linked to ~3.7-fold higher 1-year mortality vs elective use.
Why the study?
The use of mechanical circulatory support devices in elderly high-risk patients undergoing TAVR is underexplored.
Cohort (n=54)
No
Absolute Event Rate: 71% vs 19%
MCS use in select high-risk TAVR cases warrants procedural vigilance; leaves open optimal device selection and outcome impact.
OBJECTIVE: Evaluate the use of mechanical circulatory support (MCS) devices in high-risk patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: The use of MCS devices in elderly patients with multiple comorbidities undergoing TAVR is underexplored. METHODS: All patients undergoing TAVR at a single tertiary academic center who required MCS during index procedure between 2008 and 2015 were included in a prospective database. RESULTS: MCS was used in 9.4% (54/577) of all TAVRs (n = 52 Edwards Sapien and n = 2 CoreValves) of which 68.5% (n = 37) were used as part of a planned strategy, and 31.5% (n = 17) were used in emergency "bail-out" situations. IABP was the most commonly used device (87%) followed by Impella and ECMO (6% each). Among the MCS group, 22% required cardiopulmonary resuscitation during the procedure (n = 4 elective [11%] vs. n = 8 emergent [47%]) and 15% upgrade to a second device (Impella or CPB after IABP; n = 5 elective [14%] vs. n = 3 emergent [18%]). Median duration of support was 1-day. Device related complications were low (4%). In-hospital mortality in this extremely high-risk population was 24% (13/54) (11% [4/37] for elective cases and 53% [9/17] for emergency cases). Cardiogenic shock (50%) was the most common cause of in-hospital death. Cumulative all-cause 1-year mortality was 35% (19/54) (19% 97/370 for elective and 71% [12/17] for emergency cases). CONCLUSION: Emergent use of MCS during TAVR in extremely high-risk population is associated with high short and long-term mortality rates. Early identification of patients at risk for hemodynamic compromise may rationalize elective utilization of MCS during TAVR.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2016) conducted a cohort in High-risk patients undergoing transcatheter aortic valve replacement (TAVR) requiring mechanical circulatory support (n=54). Emergent mechanical circulatory support vs. Elective mechanical circulatory support was evaluated on Cumulative all-cause 1-year mortality. Emergent use of mechanical circulatory support during TAVR was associated with a higher 1-year all-cause mortality compared to elective use (71% vs 19%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: